Abstract

BACKGROUND

A study was performed to measure metal ions present in the knee joint after performing a total knee arthroplasty (TKA) with standard cobalt chromium (CoCr) components as well as with "nickel-free" oxidized zirconium femoral and titanium tibial (OxZr/Ti) components.

METHODS

Knee joint fluid was collected prior to arthrotomy, and on postoperative day one to determine the amount of metal debris generated when performing a TKA with standard instrumentation from consecutive cases with CoCr components (n = 24) and OxZr/Ti components (n = 16).

RESULTS

CoCr implant patients had statistically higher levels of nickel (Ni) (29.7%, P = .033), cobalt (Co), (1,100.7%, P < .0001) and chromium (Cr) (118.9%, P < .0001) postoperatively. The cutting blocks and sawblades do not contain Co, which therefore must have come from the components. The metal ions generated from the sawblades and cutting blocks, therefore, could be discerned from the OxZr/Ti whose components don't contain Co, Cr, or Ni. The OxZr patients had significantly higher Cr (9.5×, P < .001) and Ni (5.1×, P < .001) post-TKA vs pre-TKA; Co levels were not significantly different as expected with the absence of Co in the components (P = .60). The Ni levels generated in performing an Oxinium TKA was 3.3 times higher than when performing a CoCr TKA (1.37 vs. 41 ppb, P < .001).

CONCLUSIONS

The substantial degree of Ni generation resulting from performing a hypoallergenic "nickel-free" TKA calls into questions the rationale of utilizing more expensive lower Ni components on the basis of known or suspected Ni or Cr allergy.

摘要

背景

本研究旨在测量全膝关节置换术(TKA)中使用标准钴铬(CoCr)组件以及“无镍”氧化锆股骨和钛胫骨(OxZr/Ti)组件后膝关节内存在的金属离子。

方法

在关节切开术之前和术后第 1 天收集膝关节液,以确定使用标准器械进行 TKA 时产生的金属碎片量,病例为使用 CoCr 组件(n=24)和 OxZr/Ti 组件(n=16)的连续病例。

结果

CoCr 植入物患者术后镍(Ni)(29.7%,P=0.033)、钴(Co)(1100.7%,P<0.0001)和铬(Cr)(118.9%,P<0.0001)水平显著升高。切割块和锯片不含 Co,因此必须来自组件。从 OxZr/Ti 中可以分辨出来自锯片和切割块的金属离子,因为 OxZr/Ti 组件不含 Co、Cr 或 Ni。OxZr 患者术后 Cr(9.5×,P<0.001)和 Ni(5.1×,P<0.001)明显升高,与组件中不含 Co 相符(P=0.60)。与 CoCr TKA 相比,执行 Oxinium TKA 时产生的 Ni 水平高 3.3 倍(1.37 比 41 ppb,P<0.001)。

结论

由于进行低致敏性“无镍”TKA 而导致的 Ni 大量产生,使得在已知或疑似镍或铬过敏的情况下,使用更昂贵的低 Ni 组件的合理性受到质疑。