Suppr超能文献

Triggered electromyography (tEMG) in the lumbar spine It́s reliable? Correlation of tEMG with postoperative CT images in lumbar instrumentation.

作者信息

Beaulieu Lalanne L, Larrondo Carmona R, Alvarez Lemos F, Oelker Behn C, Cáceres Copetta M, Muñoz Wilson J T, Beaulieu Montoya A M, Larrondo Martinez V

机构信息

Departamento de Cirugía de Columna, Clínica Universidad de los Andes, Santiago, Chile.

Departamento de Cirugía de Columna, Clínica Universidad de los Andes, Santiago, Chile.

出版信息

Rev Esp Cir Ortop Traumatol. 2022 Mar-Apr;66(2):143-148. doi: 10.1016/j.recot.2021.09.010. Epub 2021 Dec 8.

Abstract

INTRODUCTION

Instrumentation with pedicle screws (PS) can compromise the adjacent neural structures. Triggered electromyography (tEMG) is a modality of intraoperative neuromonitoring, used to assist in the placement of these. The objective of the present study is to evaluate the reliability of this tool.

METHOD

Retrospective review of patients underwent posterior lumbar fusions from January 2017 to December 2019, correlating postoperative CT images (postop CT) with tEMG results for each PS with a threshold of 10mA, establishing sensitivity and specificity of this tool. Diagnostic test and receiver operating characteristic curve were performed to evaluate the area under the curve.

RESULT

A total of 275 PS were evaluated between L1 to S1; 5 PS showed concordance for an inadequate trajectory, while 10PS, with tEMG <10mA, were correctly positioned. The postoperative CT identified 17 pedicle gaps not noticed by the tEMG. Sensitivity and specificity were 23% (95% CI: 8-45) and 96% (95% CI: 93-98), respectively, with a PPV of 33.3% and a NPV of 93.6%. The area under the curve was 0.74 (95% CI: 0.62-0.86) with a cut-off point of 24mA, showing a sensitivity of 77% (95% CI: 0.55-0.92) and specificity of 69% (95% CI: 0.63-0.75).

CONCLUSION

Given its low sensitivity, we do not recommend tEMG as the sole test in the verification of PS. We recommend using a cut-off point ≤8mA as it demonstrated the highest levels of sensitivity and specificity. We do not recommend using high thresholds to increase sensitivity.

摘要

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验