National Centre for Food Science, Singapore Food Agency, 10 Perahu Road, Singapore 718837, Singapore.
Molecules. 2022 Apr 14;27(8):2539. doi: 10.3390/molecules27082539.
The engineered silver nanoparticles (AgNPs) have been widely used in various food contact materials (FCMs) based on their antibacterial properties. This widespread use of nanosilver has, however, increased the risk of exposure of AgNPs to human due to their migration from FCMs causing a potential hazard present in foods. Therefore, it is important to establish a reliable and practical method for the detection of AgNPs in food matrices to support risk assessment on AgNPs exposure. Taking the examples of milk and AgNPs-containing breast milk storage bags, this study established an approach for size characterization and quantification of AgNPs in milk and evaluated the relevant silver migration, based on enzymatic digestion and the analysis by asymmetric flow field-flow fractionation (AF4) hyphenated with inductively coupled plasma mass spectrometry (ICP-MS) and single particle inductively coupled plasma mass spectrometry (SP-ICP-MS). No migration of AgNPs was found from breast milk storage bags under various simulated storage conditions as well as extreme scenarios. The suitability and reliability of this method were also validated by the determination of multiple parameters, including accuracy, repeatability, limit of detection (LOD), limit of quantification (LOQ), and recovery, for AF4-ICP-MS and SP-ICP-MS, respectively, with good and overall acceptable evaluation results obtained for all. The established and validated approach was demonstrated to be suitable for the characterization and quantitation of AgNPs in milk as well as the analysis of their migration from breast milk storage bags.
基于其抗菌特性,工程化的银纳米颗粒(AgNPs)已被广泛应用于各种食品接触材料(FCM)中。然而,由于纳米银从 FCM 中迁移出来,增加了人体接触 AgNPs 的风险,从而对食品中的潜在危害构成了威胁。因此,建立一种可靠且实用的方法来检测食品基质中的 AgNPs,以支持对 AgNPs 暴露的风险评估非常重要。以牛奶和含 AgNPs 的母乳储存袋为例,本研究建立了一种在牛奶中对 AgNPs 进行大小表征和定量分析的方法,并评估了相关的银迁移情况,该方法基于酶消化和不对称流场流分离(AF4)与电感耦合等离子体质谱(ICP-MS)和单颗粒电感耦合等离子体质谱(SP-ICP-MS)联用。在各种模拟储存条件以及极端情况下,均未发现母乳储存袋中有 AgNPs 迁移。通过分别对 AF4-ICP-MS 和 SP-ICP-MS 进行多个参数的测定,包括准确性、重复性、检出限(LOD)、定量限(LOQ)和回收率,验证了该方法的适用性和可靠性,所有参数的评估结果均良好且总体可接受。所建立和验证的方法适用于牛奶中 AgNPs 的表征和定量分析,以及母乳储存袋中 AgNPs 迁移的分析。