Indocyanine green videoangiography (ICG-VA) with FLOW 800 (Carl Zeiss AG) has been used as a visualization tool to guide arteriovenous malformation (AVM) surgery since 2011. We performed a systematic review and evaluated the quality of evidence available on this topic. In addition, we present a series of our own cases demonstrating the unique use of ICG-VA in the localization and removal of deeper seated AVMs.
Using the PRISMA (Preferred Reporting Items for Systematic reviews and Meta-Analyses) guidelines for systematic reviews, we identified studies related to ICG-VA with FLOW 800 in AVM surgeries using search terms. The studies were screened and reviewed, and the quality of evidence was analyzed using the GRADE (Grading of Recommendations Assessment, Development, and Evaluation) criteria. We performed a retrospective review of our own cases of AVM removal with ICG-VA and FLOW 800.
Our search revealed 27 relevant studies, 17 of which met our inclusion criteria. The quality of the body of evidence was determined to be "very low" using the GRADE criteria. We used ICG-VA with FLOW 800 analysis for 14 cases of microsurgical AVM removal. This technique provided unique insights into the localization of deep seated AVMs in 8 cases (57%). No residual AVM was found when assessed by the 6-month follow-up angiogram.
We present cases highlighting the usefulness of this technique for the localization of certain AVMs. We believe the use of ICG-VA can guide the removal of deeper seated AVMs, because it can reveal surface feeders and draining veins that can be followed to a hidden nidus. Larger, registry-based studies are needed to confirm these findings and improve the overall quality of evidence.
自 2011 年以来,吲哚菁绿视频血管造影(ICG-VA)与 FLOW 800(卡尔蔡司公司)已被用作引导动静脉畸形(AVM)手术的可视化工具。我们进行了系统评价,并评估了这一主题的现有证据质量。此外,我们还展示了一系列我们自己的病例,展示了 ICG-VA 在定位和切除深部 AVM 方面的独特应用。
使用 PRISMA(系统评价和荟萃分析的首选报告项目)指南,我们使用搜索词确定了与 FLOW 800 中 ICG-VA 相关的 AVM 手术研究。对研究进行筛选和审查,并使用 GRADE(推荐评估、制定和评估分级)标准分析证据质量。我们对我们自己的 ICG-VA 和 FLOW 800 切除 AVM 的病例进行了回顾性回顾。
我们的搜索发现了 27 项相关研究,其中 17 项符合我们的纳入标准。使用 GRADE 标准,确定证据体的质量为“极低”。我们使用 ICG-VA 与 FLOW 800 分析了 14 例显微手术 AVM 切除术。该技术为 8 例(57%)深部 AVM 的定位提供了独特的见解。6 个月的随访血管造影显示无残留 AVM。
我们展示了一些病例,强调了该技术在定位某些 AVM 方面的有用性。我们认为,ICG-VA 的使用可以指导深部 AVM 的切除,因为它可以显示表面供血动脉和引流静脉,可以追踪到隐藏的病灶。需要更大的、基于登记的研究来证实这些发现并提高整体证据质量。