Alinaghi Langari Ali Akbar, Firoozichahak Ali, Alizadeh Saber, Nematollahi Davood, Farhadian Maryam
Student Research Committee, School of Public Health, Bam University of Medical Sciences Bam Iran.
Department of Occupational Health, Faculty of Health, Social Determinants of Health Research Center, Gonabad University of Medical Science Gonabad Iran
RSC Adv. 2020 Apr 3;10(23):13562-13572. doi: 10.1039/d0ra00687d. eCollection 2020 Apr 1.
In this study, development of a needle trap device (NTD) packed with UiO-66 adsorbent was used for the sampling of the aromatic amine compounds (including aniline, ,-dimethylaniline and -toluidine) followed by gas chromatography (GC) with flame-ionization detector (FID) analysis. The UiO-66 sorbent was synthesized and then packed inside a spinal needle (Gauge 22). The synthesized sorbent was characterized with the XRD, FE-SEM, EDS and FT-IR techniques. This study was conducted both in the laboratory and in the real samples. In the laboratory, the sampling parameters (such as temperature and humidity) and desorption parameters (including desorption temperature and desorption time) were optimized using Response Surface Methodology (RSM) by Central Composite Design (CCD). The results indicated that the performance of the sampling device decreased with increasing the sampling humidity and temperature. Moreover, the highest peak area responses of the studied analytes were observed at a desorption time of 3 minutes and desorption temperature of 270 °C. The values of the limit of detection (LOD) and limit of quantitation (LOQ) were in the range 0.01-0.02 and 0.03-0.05 ng mL, respectively. Our findings demonstrated that NTD packed with synthesized UiO-66 has good repeatability (RSD = 1.3-6.8%) and acceptable reproducibility (with three NTDs) (RSD = 1.3-9.7%). Comparison of the results between NTD-UiO-66 and NIOSH2002 showed a sufficient correlation (0.98-0.99) between two methods. Therefore, the results indicated that the NTD packed with the UiO-66 adsorbent can be used as a powerful technique for occupational and environmental monitoring.
在本研究中,使用填充有UiO - 66吸附剂的针捕集装置(NTD)对芳香胺化合物(包括苯胺、N,N - 二甲基苯胺和对甲苯胺)进行采样,随后采用带有火焰离子化检测器(FID)的气相色谱(GC)进行分析。合成了UiO - 66吸附剂,然后将其填充在22号脊椎穿刺针内。采用XRD、FE - SEM、EDS和FT - IR技术对合成的吸附剂进行了表征。本研究在实验室和实际样品中均进行。在实验室中,使用响应面方法(RSM)通过中心复合设计(CCD)对采样参数(如温度和湿度)和解吸参数(包括解吸温度和解吸时间)进行了优化。结果表明,采样装置的性能随采样湿度和温度的升高而降低。此外,在解吸时间为3分钟、解吸温度为270℃时,观察到所研究分析物的最高峰面积响应。检测限(LOD)和定量限(LOQ)的值分别在0.01 - 0.02和0.03 - 0.05 ng/mL范围内。我们的研究结果表明,填充合成UiO - 66的NTD具有良好的重复性(RSD = 1.3 - 6.8%)和可接受的重现性(使用三个NTD)(RSD = 1.3 - 9.7%)。NTD - UiO - 66与NIOSH2002之间的结果比较表明,两种方法之间具有充分的相关性(0.98 - 0.99)。因此,结果表明,填充UiO - 66吸附剂的NTD可作为职业和环境监测的有力技术。