Faculty of Dentistry, Mansoura University, Mansoura, Egypt.
Faculty of Dentistry, Modern University for Technology and Information, Cairo, Egypt.
Clin Implant Dent Relat Res. 2022 Jun;24(3):391-400. doi: 10.1111/cid.13089. Epub 2022 May 3.
The aim of this was to compare the influence of two different angulated abutment designs on patient satisfaction, oral health-related quality of life, and prosthetic aspects of implant-supported maxillary overdentures.
For this cross-over study, 18 patients with completely edentulous maxillary ridges opposing implant-retained mandibular overdentures received 4 implants between the maxillary sinuses using computer-guided surgery. The anterior implants were installed at canine/lateral incisor areas and inclined 15° labially. The posterior implants were inserted just anterior to the maxillary sinuses and inclined 15o distally. Eight patients received maxillary overdentures retained by angled ball attachment (ball overdenture [BOD]) and angled locator attachment in random order. After 6 months, patients indicated satisfaction with their prosthesis using a visual analog scale (VAS), and oral health impact profile (OHIP-14). Moreover, postinsertion prosthodontic maintenance and complications were recorded for both attachments. Comparisons of patient satisfaction and prosthetic complications between groups were performed using the Wilcoxon matched-pairs test and the McNemar test, respectively.
Locator overdenture (LOD) recorded significantly higher scores than the BOD group regarding all the VAS questions except for ease of cleaning (p < 0.007). LOD recorded significantly higher patient satisfaction regarding the pronunciation of sounds (p = 0.009), painful aching (p = 0.018), feeling tense (p = 0.011), unsatisfactory diet (p = 0.013), irritability with people (p = 0.005), and life in general (p = 0.004). The most common complications were matrix activation/renewal (n = 34). BOD showed a significantly higher incidence of attachment loosening (p = 0.002), and teeth fracture (p = 0.049) than LOD. LOD showed a significantly higher incidence of attachment wear and replacement than BOD (p <0.001). There was no difference between groups regarding soft tissue complications.
Within the limitations of this study, and in terms of improved patient-centered outcomes, angled locator attachments are recommended to retain maxillary implant overdentures opposed by implant retained mandibular overdentures at it was associated with increased patient satisfaction and oral health-related quality of life than angled ball attachments. However, locator attachment was associated with more postinsertion prosthodontic maintenance than ball attachment.
本研究旨在比较两种不同角度基台设计对上颌覆盖义齿患者满意度、口腔健康相关生活质量和修复方面的影响。
本交叉研究纳入 18 名上颌牙槽嵴完全缺失、下颌佩戴种植体支持覆盖义齿的患者,采用计算机引导手术植入 4 枚种植体。前牙种植体安装在犬齿/侧切牙区域,向唇侧倾斜 15°。后牙种植体植入上颌窦前,向远中倾斜 15°。8 名患者随机接受角度球附着体(球附着体[BOD])或角度Locator 附着体保留的上颌覆盖义齿。6 个月后,患者使用视觉模拟量表(VAS)和口腔健康影响量表(OHIP-14)对义齿满意度进行评价。此外,还记录了两种附着体的义齿修复后维护和并发症情况。采用 Wilcoxon 配对检验和 McNemar 检验分别比较两组患者满意度和修复体并发症。
Locator 附着体(LOD)在除清洁难易度外的所有 VAS 问题上的评分均显著高于 BOD 组(p<0.007)。LOD 在发音清晰度(p=0.009)、疼痛不适(p=0.018)、紧张感(p=0.011)、饮食满意度(p=0.013)、与他人相处时烦躁感(p=0.005)和生活满意度(p=0.004)等方面的患者满意度显著高于 BOD 组。最常见的并发症是基台的激活/更换(n=34)。BOD 组附着体松动(p=0.002)和牙齿折裂(p=0.049)的发生率显著高于 LOD 组。LOD 组附着体磨损和更换的发生率显著高于 BOD 组(p<0.001)。两组软组织并发症无差异。
在本研究的限制范围内,从以患者为中心的结果角度来看,建议使用角度Locator 附着体保留上颌覆盖义齿,因为与角度球附着体相比,它可以提高患者满意度和口腔健康相关生活质量。然而,Locator 附着体的修复后维护比球附着体更频繁。