Total phosphorus is one of the key water quality parameters in environmental monitoring. To precisely determine the total phosphorus, water samples have to be pretreated to convert the various forms of phosphorus to orthophosphate. Conventionally, pretreatment is accomplished by heating, acidification, and oxidation in a digestion equipment, which is dangerous, time-consuming, and complicated. Herein, we propose a novel high-performance electrochemical oxidation protocol for phosphorus digestion based on a PbO electrode. The electrode, which has a hydrophobic and stable surface, was prepared by electrochemical deposition on a titanium substrate and has high hydroxyl radical utilization when digesting total phosphorus. As a result, 90% of sodium glycerophosphate was digested within 30 minutes, and high digestion ratios of acephate, glyphosate, and inland water samples were obtained as well. In addition, this electrochemical digestion protocol does not required heating and acidification steps, which shortens the digestion time. Therefore, a rapid quantification of total phosphorus in the water sample was achieved.
总磷是环境监测中的关键水质参数之一。为精确测定总磷,水样必须经过预处理,将各种形态的磷转化为正磷酸盐。传统上,预处理是通过在消解设备中加热、酸化和氧化来完成的,这种方法危险、耗时且复杂。在此,我们提出了一种基于PbO电极的新型高效电化学氧化磷消解方案。该电极通过在钛基底上进行电化学沉积制备而成,具有疏水且稳定的表面,在消解总磷时具有较高的羟基自由基利用率。结果,甘油磷酸钠在30分钟内有90%被消解,对乙酰甲胺磷、草甘膦和内陆水样也获得了较高的消解率。此外,这种电化学消解方案不需要加热和酸化步骤,缩短了消解时间。因此,实现了对水样中总磷的快速定量分析。