Suppr超能文献

智能环保分光光度法解析高度重叠光谱:在兽医抗生素注射中的应用。

Smart Eco-Friendly Spectrophotometric Methods Resolving Highly Overlapping Spectra: Application to Veterinary Antibiotic Injections.

机构信息

Ahram Canadian University, Faculty of Pharmacy, Pharmaceutical Chemistry Department, Cairo 12451, Egypt.

Ain Shams University, Faculty of Pharmacy, Pharmaceutical Analytical Chemistry Department, Cairo 11566, Egypt.

出版信息

J AOAC Int. 2022 Sep 6;105(5):1234-1246. doi: 10.1093/jaoacint/qsac058.

Abstract

BACKGROUND

Over the last few years, mathematical manipulation has proved to be a very powerful means of successfully resolving severely overlapped spectra for various multicomponent mixtures.

OBJECTIVE

Smart and environmentally friendly spectrophotometric determination approaches were used for two binary mixtures of fixed dose veterinary injections containing flunixin meglumine (FLU) combined with either florfenicol (FLR), or oxytetracycline HCl (OXY).

METHODS

Regarding the first mixture, both FLU and FLR were determined by three successive resolution techniques, which were; constant multiplication coupled with spectrum subtraction (CM-SS), derivative ratio (DD1), and ratio difference (RD), and two progressive resolution techniques which were absorbance subtraction (AS) and amplitude modulation (AM). Also, graphical representation of concentration of the two drugs through concentration value (CNV) method was also applied. Concerning the second mixture, both FLU and OXY showed severely overlapped spectra and a comparative study was conducted for the determination of each drug by constant center (CC), ratio subtraction via amplitude difference coupled with spectrum subtraction (RS/AD-SS), constant value via amplitude difference (CV-AD), and advanced concentration value (ACV) methods.

RESULTS

Calibration graphs of the first mixture were linear over the range 5-40 µg/mL for FLU, and 3-40 µg/mL for FLR. The proposed methods overcame the problem of the overlapped spectra and the presence of a minor component in the mixture. Regarding the second mixture, calibration graphs were linear over the range 2.5-24 µg/mL for FLU and 4-28 µg/mL for OXY.

CONCLUSION

The proposed methods were successfully validated as per International Council for Harmonization (ICH) guidelines. The obtained results were statistically compared with the official or reported methods, showing no significant difference concerning accuracy and precision. The methods were evaluated for greenness by three different assessment tools: NEMI, analytical ecoscale, and GAPI.

HIGHLIGHTS

The methods were successfully applied for the simultaneous determination of the two combinations in synthetic mixtures and their marketed antibiotic veterinary injections: Megluflor® and Floxon®.

摘要

背景

在过去的几年中,数学处理已被证明是成功解析各种多组分混合物严重重叠光谱的非常有效的手段。

目的

使用智能且环保的分光光度测定方法,对含有氟尼辛(FLU)的两种固定剂量兽用注射剂的两种二元混合物进行测定,混合物中分别含有氟苯尼考(FLR)或盐酸土霉素(OXY)。

方法

对于第一种混合物,FLU 和 FLR 均通过三种连续分辨率技术进行测定,分别为:常数乘法与光谱减法(CM-SS)、导数比(DD1)和比率差(RD),以及两种连续分辨率技术,分别为吸光度减法(AS)和幅度调制(AM)。此外,还应用浓度值(CNV)法通过浓度值(CNV)法对两种药物的浓度进行图形表示。对于第二种混合物,FLU 和 OXY 的光谱严重重叠,对每种药物的测定进行了恒中(CC)、通过幅度差与光谱减法进行比率减法(RS/AD-SS)、通过幅度差进行恒值(CV-AD)和高级浓度值(ACV)方法的对比研究。

结果

第一种混合物的校准曲线在 FLU 的 5-40μg/mL 和 FLR 的 3-40μg/mL 范围内呈线性。所提出的方法克服了重叠光谱和混合物中少量成分存在的问题。对于第二种混合物,校准曲线在 FLU 的 2.5-24μg/mL 和 OXY 的 4-28μg/mL 范围内呈线性。

结论

所提出的方法已根据国际协调会议(ICH)指南成功验证。所得结果与官方或报道的方法进行了统计学比较,在准确性和精密度方面没有显着差异。该方法通过三种不同的评估工具:NEMI、分析生态标度和 GAPI 进行了绿色评估。

重点

该方法成功应用于合成混合物和市售抗生素兽用注射剂中两种组合的同时测定:Megluflor®和 Floxon®。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验