Suppr超能文献

比较有中心静脉导管的儿科患者 29 项生化分析物的采血管。

Comparison of blood collection tubes for 29 biochemical analytes in pediatric patients with central venous catheters.

机构信息

Department of Laboratory Medicine, Yonsei University College of Medicine, Seoul, South Korea.

Department of Pediatrics, Yonsei University College of Medicine, Seoul, South Korea.

出版信息

Clin Biochem. 2022 Sep;107:73-79. doi: 10.1016/j.clinbiochem.2022.04.017. Epub 2022 May 8.

Abstract

BACKGROUND

Pediatric cancer patients undergoing chemotherapy or radiation therapy generally require a central venous catheter (CVC). However, serum drawn from CVCs has several drawbacks for use in routine chemistry tests. Biochemical analytes were evaluated using heparin plasma instead of serum to maintain turnaround time and to prevent problems caused by micro-clot formation or delayed clotting time.

METHODS

Venous blood samples from 52 pediatric oncology patients with chemoports or Hickman catheters were collected in serum separating tubes (SSTs) and lithium heparin tubes (LHTs). A total of 29 parameters were analyzed on a Cobas c702 (Roche Diagnostics, Mannheim, Germany). Passing-Bablok regression and Bland-Altman difference plots were used for statistical analyses.

RESULTS

When the mean value of each analyte measured from LHT was compared with those from SST, percentage bias was within the desirable bias limit in most of the analytes. However, albumin, potassium, and inorganic phosphorus showed a negative constant bias of -3.0%, -5.3%, and -1.6%, respectively, and total protein showed a positive constant bias of + 3.8%.

CONCLUSIONS

The use of LHTs for sample collection from pediatric patients with CVCs could be helpful for routine chemistry analyses. The results of potassium and total protein should be interpreted with consideration of the difference between serum and plasma samples.

摘要

背景

接受化疗或放疗的儿科癌症患者通常需要中心静脉导管(CVC)。然而,从 CVC 采集的血清在用于常规化学测试时有几个缺点。使用肝素血浆而不是血清来评估生化分析物,以维持周转时间并防止因微凝块形成或凝血时间延迟而导致的问题。

方法

采集 52 例有化疗港或 Hickman 导管的儿科肿瘤患者的静脉血样,分别置于血清分离管(SST)和肝素锂管(LHT)中。使用 Cobas c702(罗氏诊断公司,曼海姆,德国)分析总共 29 个参数。使用 Passing-Bablok 回归和 Bland-Altman 差异图进行统计分析。

结果

当将从 LHT 测量的每个分析物的平均值与 SST 进行比较时,大多数分析物的百分比偏差都在可接受的偏差范围内。然而,白蛋白、钾和无机磷分别显示出-3.0%、-5.3%和-1.6%的负恒定偏差,总蛋白显示出+3.8%的正恒定偏差。

结论

对于有 CVC 的儿科患者,使用 LHT 采集样本有助于进行常规化学分析。应考虑血清和血浆样本之间的差异来解释钾和总蛋白的结果。