去污方法对临床失败的钛锆合金表面处理种植体的清洁效果及其对表面粗糙度和化学成分的影响:一项体外初步研究。

Cleaning effects of decontamination methods on clinically failed TiUnite implants and their impacts on surface roughness and chemistry: An in vitro pilot study.

作者信息

Qian Yinjie, Tong Zian, Cai Bobo, Zhu Weijun, Si Misi

出版信息

Int J Oral Implantol (Berl). 2022 May 13;15(2):149-165.

Abstract

PURPOSE

To evaluate the in vitro cleaning effects of different decontamination methods and their impacts on surface characteristics using clinically failed TiUnite implants (Nobel Biocare, Kloten, Switzerland).

MATERIALS AND METHODS

Thirty clinically failed TiUnite implants were treated using different decontamination methods. Group 1 (control group) received physiological saline irrigation; Group 2 underwent erythritol powder air polishing (AIRFLOW Master Piezon, EMS Dental, Nyon, Switzerland); Group 3 was treated with erythritol powder air polishing with ethylenediaminetetraacetic acid brushing (FileRite PRC, Pulpdent, Watertown, MA, USA); Group 4 received ultrasonic scaling with polyetheretherketone tips (EMS Dental); Group 5 underwent ultrasonic scaling with polyetheretherketone tips with ethylenediaminetetraacetic acid; and Group 6 was treated with a combination of ultrasonic scaling with polyetheretherketone tips, erythritol powder air polishing and ethylenediaminetetraacetic acid. Surface cleaning effects, quantified by relative contaminated area reduction and visual analogue scale score, as well as surface roughness and chemistry, were assessed after decontamination. The cleaning effects of each decontamination method were also compared between TiUnite and SLA (sandblasted, large-grit acid-etched; Straumann, Basel, Switzerland) implants.

RESULTS

Group 6 showed the highest relative contaminated area reduction (stereoscopic microscopy 83.92%, scanning electron microscopy 96.40%), visual analogue scale score (2.83) and reduction in surface roughness (thread bottom -0.78 μm, tip -1.35 μm), as well as an almost maximal decrease in the proportion of carbon (thread bottom -12.33%, tip -8.77%) and increase in that of titanium (thread bottom 13.71%, tip 10.73%). Polyetheretherketone remnants were observed in Groups 4 and 5 but appeared to be reduced in Group 6. When comparing the outcomes with those for SLA implants, no significant differences were found.

CONCLUSION

Within the limitations of the present study, the combination of ultrasonic scaling with polyetheretherketone tips, erythritol powder air polishing and ethylenediaminetetraacetic brushing achieved reasonable cleaning effects. The original surface modification did not seem to have any impact on the decontamination results for any of the methods examined.

摘要

目的

使用临床上失败的钛易耐(TiUnite)种植体(诺贝尔生物科技公司,克洛滕,瑞士)评估不同去污方法的体外清洁效果及其对表面特性的影响。

材料与方法

对30颗临床上失败的钛易耐种植体采用不同的去污方法进行处理。第1组(对照组)接受生理盐水冲洗;第2组进行赤藓糖醇粉末空气抛光(AIRFLOW Master Piezon,EMS Dental公司,尼永,瑞士);第3组采用赤藓糖醇粉末空气抛光并结合乙二胺四乙酸刷牙(FileRite PRC,Pulpdent公司,沃特敦,马萨诸塞州,美国);第4组使用聚醚醚酮尖端进行超声洁治(EMS Dental公司);第5组使用聚醚醚酮尖端并结合乙二胺四乙酸进行超声洁治;第6组采用聚醚醚酮尖端超声洁治、赤藓糖醇粉末空气抛光和乙二胺四乙酸联合处理。去污后评估表面清洁效果,通过相对污染面积减少和视觉模拟评分进行量化,以及表面粗糙度和化学成分。还比较了钛易耐种植体和SLA(喷砂、大颗粒酸蚀;士卓曼公司,巴塞尔,瑞士)种植体之间每种去污方法的清洁效果。

结果

第6组显示出最高的相对污染面积减少(立体显微镜下为83.92%,扫描电子显微镜下为96.40%)、视觉模拟评分(2.83)和表面粗糙度降低(螺纹底部 -0.78μm,尖端 -1.35μm),以及碳比例几乎最大程度的降低(螺纹底部 -12.33%,尖端 -8.77%)和钛比例的增加(螺纹底部13.71%,尖端10.73%)。在第4组和第5组中观察到聚醚醚酮残留,但在第6组中似乎有所减少。与SLA种植体的结果相比,未发现显著差异。

结论

在本研究的局限性内,聚醚醚酮尖端超声洁治、赤藓糖醇粉末空气抛光和乙二胺四乙酸刷牙联合使用取得了合理的清洁效果。原始表面改性似乎对所研究的任何方法的去污结果均无影响。