Suppr超能文献

基于二维和点剪切波弹性成像测量诊断食管静脉曲张的准确性:一项系统评价和荟萃分析。

Accuracy of 2D and point shear wave elastography-based measurements for diagnosis of esophageal varices: a systematic review and meta-analysis.

作者信息

Zhang Xing, Chen Chunxiao, Yan Chungen, Song Taoyan

机构信息

Department of Gastroenterology, Affiliated Hospital of Shaoxing University, Zhejiang, China.

The First Affiliated Hospital of Zhejiang University School of Medicine, Zhejiang, China.

出版信息

Diagn Interv Radiol. 2022 Mar;28(2):138-148. doi: 10.5152/dir.2022.21730.

Abstract

PURPOSE The aim of this meta-analysis is to summarize the diagnostic accuracies of point shear wave elas- tography (pSWE) and two-dimensional (2D) SWE for esophageal varices (EV) and varices needing treatment (VNT). METHODS We conducted a systematic review and meta-analysis of diagnostic accuracy studies. We searched for studies reporting the EV and VNT diagnostic accuracy of pSWE and 2D SWE using PubMed Cen- tral, SCOPUS, MEDLINE, Embase, and Cochrane databases. STATA software"Midas"package was used for meta-analysis. RESULTS A total of 24 studies with 3867 patients were included in the review. Pooled score sensitivities of pSWE were 91% (95% CI, 80%-96%) for EV, and 94% (95% CI, 86%-97%) for VNT. Pooled score sensi- tivities of 2D SWE were 78% (95% CI, 69%-85%) for EV, and 79% (95% CI, 72%-85%) for VNT. Pooled score specificities of pSWE were 70% (95% CI, 60%-78%) for EV, and 59% (95% CI, 40%-75%) for VNT. Pooled score specificities of 2D SWE for EV were 79% (95% CI, 72%-85%) 72% (95% CI, 66%-77%) for VNT. We found significant heterogeneity for all the elastography-based measurements with the chi- square test results and an I2 statistic >75%. CONCLUSION Both pSWE and 2D SWE can diagnose EV and VNT with moderate diagnostic accuracy. Further large- scale setting-specific longitudinal studies are required to establish the best modality.

摘要

目的 本荟萃分析旨在总结点剪切波弹性成像(pSWE)和二维(2D)剪切波弹性成像对食管静脉曲张(EV)和需要治疗的静脉曲张(VNT)的诊断准确性。方法 我们对诊断准确性研究进行了系统评价和荟萃分析。使用PubMed Central、SCOPUS、MEDLINE、Embase和Cochrane数据库检索报告pSWE和2D SWE对EV和VNT诊断准确性的研究。采用STATA软件的“Midas”包进行荟萃分析。结果 本评价共纳入24项研究,3867例患者。pSWE对EV的合并评分敏感性为91%(95%CI,80%-96%),对VNT为94%(95%CI,86%-97%)。2D SWE对EV的合并评分敏感性为78%(95%CI,69%-85%),对VNT为79%(95%CI,72%-85%)。pSWE对EV的合并评分特异性为70%(95%CI,60%-78%),对VNT为59%(95%CI,40%-75%)。2D SWE对EV的合并评分特异性为79%(95%CI,72%-85%),对VNT为72%(95%CI,66%-77%)。我们发现基于弹性成像的所有测量结果在卡方检验结果和I2统计量>75%时有显著异质性。结论 pSWE和2D SWE均可对EV和VNT进行诊断,诊断准确性中等。需要进一步开展大规模特定环境下的纵向研究以确定最佳模式。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验