Abstract

The extensive use of herbicides, such as glyphosate and glufosinate, in crop production during recent decades has raised concerns about human exposure. Nevertheless, analysis of trace levels of these herbicides in human biospecimens has been challenging. Here, we describe a method for the determination of urinary glyphosate, its degradation product aminomethylphosphonic acid (AMPA), and glufosinate using liquid chromatography-tandem mass spectrometry (LC−MS/MS). The method was optimized using isotopically labelled internal standards (13C2, 15N-glyphosate, 13C, 15N, D2-AMPA, and D3-glufosinate) and solid-phase extraction (SPE) with cation-exchange and anion-exchange cartridges. The method provides excellent chromatographic retention, resolution and peak shape of target analytes without the need for strong acidic mobile phases and derivatization steps. The instrument linearity was in the range of 0.1−100 ng/mL, with R > 0.99 in the matrix for all analytes. The method detection limits (MDLs) and the method quantification limits (MQLs) were in the ranges of 0.12 (AMPA and glufosinate)−0.14 (glyphosate) ng/mL and 0.40 (AMPA)−0.48 (glyphosate) ng/mL, respectively. The recoveries of analytes spiked into urine matrix ranged from 79.1% to 119%, with coefficients of variation (CVs) of 4−10%. Repeated analysis of samples for over 2 weeks showed intra-day and inter-day analytical variations of 3.13−10.8% and 5.93−12.9%, respectively. The matrix effects for glyphosate, AMPA, and glufosinate spiked into urine matrix averaged −14.4%, 13.2%, and 22.2%, respectively. The method was further validated through the analysis of external quality assurance proficiency test (PT) urine samples. The method offers optimal sensitivity, accuracy, and precision for the urine-based assessment of human exposure to glyphosate, AMPA, and glufosinate.

摘要

近几十年来,草甘膦和草铵膦等除草剂在作物生产中的广泛使用引发了人们对人体接触情况的担忧。然而,分析人体生物样本中这些除草剂的痕量水平一直具有挑战性。在此,我们描述了一种使用液相色谱 - 串联质谱法(LC−MS/MS)测定尿中草甘膦、其降解产物氨甲基膦酸(AMPA)和草铵膦的方法。该方法使用同位素标记的内标(13C2、15N - 草甘膦、13C、15N、D2 - AMPA和D3 - 草铵膦)以及阳离子交换和阴离子交换柱的固相萃取(SPE)进行了优化。该方法无需强酸性流动相和衍生化步骤即可提供目标分析物出色的色谱保留、分离度和峰形。仪器线性范围为0.1−100 ng/mL,所有分析物在基质中的R > 0.99。方法检测限(MDLs)和方法定量限(MQLs)分别在0.12(AMPA和草铵膦)−0.14(草甘膦)ng/mL和0.40(AMPA)−0.48(草甘膦)ng/mL范围内。加标到尿液基质中的分析物回收率在79.1%至119%之间,变异系数(CVs)为4−10%。对样品进行超过2周的重复分析显示日内和日间分析变异分别为3.13−10.8%和5.93−12.9%。加标到尿液基质中的草甘膦、AMPA和草铵膦的基质效应平均分别为−14.4%、13.2%和22.2%。该方法通过对外部质量保证能力验证测试(PT)尿液样本的分析进一步得到验证。该方法为基于尿液评估人体接触草甘膦、AMPA和草铵膦提供了最佳的灵敏度、准确度和精密度。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/6ac5/9104544/48852bbe28e8/ijerph-19-04966-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验