Suppr超能文献

原发性后天性鼻泪管阻塞病例中泪囊加压时的自反流:与医生检查及患者感知的相关性

Self-regurgitation on pressure over lacrimal sac in cases of primary-acquired nasolacrimal duct obstruction: Correlation with physician examination and patients' perceptions.

作者信息

Alam Md S, Singh Parinita, Amitava Abadan K, Ali Mohammad J

机构信息

Orbit, Oculoplasty, Reconstructive and Aesthetic Services, Kolkata, West Bengal, India.

Aditya Birla Sankara Nethralaya, Kolkata, West Bengal, India.

出版信息

Saudi J Ophthalmol. 2021 Nov 17;35(3):217-219. doi: 10.4103/SJOPT.SJOPT_87_21. eCollection 2021 Jul-Sep.

Abstract

PURPOSE

To analyze the correlation between patient-reported regurgitation on pressure over lacrimal sac (ROPLAS) with the physician's examination in diagnosing primary-acquired nasolacrimal duct obstruction (PANDO).

METHODS

A cross-sectional study was done over 5 months (March-July 2018). All cases diagnosed as PANDO were included in the study. The maneuver of pressing over the lacrimal sac area and noticing the egress of mucoid or clear fluid from the surrounding area by the patient was termed as self-ROPLAS. A specific patient history of performance of this maneuver was compared with a clinician-performed ROPLAS and subsequent objective lacrimal drainage evaluation. The various reasons for performing self-ROPLAS by the patients were documented.

RESULTS

A total of 134 patients were included in the study, out of which 59 (44.02%) were males and 75 (55.9%) were females. History of self-ROPLAS was present in 64 (47.8%) of the patients, whereas the physician examination revealed ROPLAS to be positive in 92 (68.6%) of the patients. All patients (100%) with a positive history of self-ROPLAS had nasolacrimal duct obstruction on subsequent examination. The most common reason for performing self-ROPLAS was for emptying the discharge from the medial canthal region to reduce the painless swelling.

CONCLUSION

Self-ROPLAS is highly suggestive of an obstructed nasolacrimal duct and can be used as a screening tool by the primary physician to triage the patients toward ophthalmic plastic clinics or consult.

摘要

目的

分析患者报告的泪囊加压反流(ROPLAS)与医生检查在诊断原发性获得性鼻泪管阻塞(PANDO)中的相关性。

方法

在5个月(2018年3月至7月)内进行了一项横断面研究。所有被诊断为PANDO的病例均纳入研究。在泪囊区域加压并观察患者是否有黏液样或清亮液体从周围区域流出的操作被称为自我ROPLAS。将该操作的特定患者病史与临床医生进行的ROPLAS及随后的客观泪道引流评估进行比较。记录患者进行自我ROPLAS的各种原因。

结果

该研究共纳入134例患者,其中男性59例(44.02%),女性75例(55.9%)。64例(47.8%)患者有自我ROPLAS病史,而医生检查显示92例(68.6%)患者ROPLAS呈阳性。所有自我ROPLAS病史阳性的患者(100%)在后续检查中均有鼻泪管阻塞。进行自我ROPLAS的最常见原因是排空内眦区域的分泌物以减轻无痛性肿胀。

结论

自我ROPLAS高度提示鼻泪管阻塞,可被初级医生用作筛选工具,以便将患者分诊至眼科整形诊所或进行咨询。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/9830/9116091/43f411b5fc08/SJO-35-217-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验