Suppr超能文献

聚甲基丙烯酸甲酯的热性能因品牌和类型而异。

Thermal properties of polymethyl methacrylate vary depending on brand and type.

作者信息

Stoops Kyle, Brown Jeffrey Mark, Santoni Brandon, Groundland John

机构信息

Department of Orthopaedic Surgery, University of South Florida, Tampa, Florida, USA.

University of Miami Miller School of Medicine, Miami, Florida, USA.

出版信息

J Orthop Res. 2023 Mar;41(3):614-618. doi: 10.1002/jor.25389. Epub 2022 Jun 9.

Abstract

Polymethyl methacrylate (PMMA) is commonly used in orthopedic surgery and has several applications, most often for fixation of arthroplasty components. While its overall safety and tolerance are well described, less is known regarding the thermal properties of PMMA as it sets from a liquid to solid state, as well as the potential for osseous thermal necrosis. This study addresses potential variations in the setting time and maximum temperature of PMMA formulations in common use and explores the potential clinical implications of this variability. Seven commercially available formulations of PMMA that varied by brand and/or viscosity were obtained and prepared according to manufacturer's instructions. Peak temperature and duration were measured in controlled settings for each type and compared to previously described thresholds for thermal bone necrosis. Depuy SmartSet (HV), Zimmer Palacos R (HV), and Zimmer Palacos (LV) exceeded the 56°C threshold reported to potentially induce immediate osseous thermal necrosis. Additionally, Biomet Cobalt (MV) and Stryker Simplex P (MV) had lower peak temperatures but exceeded thermal necrosis thresholds due to curing duration. The lowest peak temperature was observed for Smith & Nephew Versabond (MV), which was significantly lower than all types except Depuy SmartSet (MV). Setting time was not significantly different among groups. There are significant differences in the thermal properties of PMMA formulations in current use. Selection of specific PMMA formulations represents an additional route of procedural optimization depending on the needs of the treating surgeon.

摘要

聚甲基丙烯酸甲酯(PMMA)常用于骨科手术,有多种应用,最常见的是用于关节置换部件的固定。虽然其总体安全性和耐受性已有充分描述,但对于PMMA从液态转变为固态时的热性能以及骨热坏死的可能性,人们了解较少。本研究探讨了常用PMMA配方在凝固时间和最高温度方面的潜在差异,并探讨了这种变异性的潜在临床意义。获得了七种因品牌和/或粘度不同的市售PMMA配方,并按照制造商的说明进行制备。在受控环境中测量每种类型的峰值温度和持续时间,并与先前描述的骨热坏死阈值进行比较。Depuy SmartSet(HV)、Zimmer Palacos R(HV)和Zimmer Palacos(LV)超过了据报道可能引发即时骨热坏死的56°C阈值。此外,Biomet Cobalt(MV)和Stryker Simplex P(MV)的峰值温度较低,但由于固化持续时间而超过了热坏死阈值。观察到Smith & Nephew Versabond(MV)的峰值温度最低,明显低于除Depuy SmartSet(MV)之外的所有类型。各组之间的凝固时间没有显著差异。目前使用的PMMA配方在热性能方面存在显著差异。根据治疗外科医生的需求,选择特定的PMMA配方是手术优化的另一条途径。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验