Hospital Israelita Albert Einstein, São Paulo, SP, Brazil.
Einstein (Sao Paulo). 2022 May 27;20:eAO6851. doi: 10.31744/einstein_journal/2022AO6851. eCollection 2022.
To evaluate whether the presence of a hypointense signal at T2-weighted imaging in a solid ovarian lesion on magnetic resonance imaging is a predictor of stability and benignity.
This is a single center study, prospectively read with retrospective acquired data. The database was searched for patients who underwent magnetic resonance imaging between January 2008 and October 2019 and whose reports mentioned solid ovarian lesions with low signal on T2-weighted imaging. A total of 47 nodules were included. A radiologist who was blinded to the clinical indication for magnetic resonance imaging and original reports evaluated the cases. Objective and subjective criteria of ovarian lesions in magnetic resonance imaging were evaluated.
Thirty-five nodules were considered benign/stable and 12 were considered non-stable. The analysis showed that the non-stable lesions showed statistically more hyperintensity at T1-weighted imaging compared to the stable lesions.
T2-weighted imaging hypointensity can be considered a predictor of stability in solid ovarian lesions when associated with iso/hypointensity in T1-weighted imaging.
评估磁共振成像中实性卵巢病变 T2 加权成像上出现低信号是否可预测其稳定性和良性。
这是一项单中心前瞻性研究,使用回顾性采集的数据。检索 2008 年 1 月至 2019 年 10 月间行磁共振成像检查且报告中提到 T2 加权成像上呈低信号实性卵巢病变的患者数据库。共纳入 47 个结节。一位对磁共振成像的临床指征和原始报告均不知情的放射科医生对这些病例进行了评估。评估了磁共振成像中卵巢病变的客观和主观标准。
35 个结节被认为是良性/稳定的,12 个被认为是非稳定的。分析表明,与稳定病变相比,非稳定病变在 T1 加权成像上显示出统计学上更多的高信号。
当 T2 加权成像呈低信号且 T1 加权成像呈等/低信号时,可将其视为实性卵巢病变稳定性的预测指标。