A stability-indicating RP-HPLC method for methylcobalamin determination was developed. Stress degradation under variable conditions was carried out. Methylcobalamin had pronounced susceptibility to hydrolysis under acidic, alkaline, and photolytic conditions; further study of photolytic degradation kinetics and pH rate profiling over pH range 2-11 was carried out. Photodegradation of methylcobalamin followed zero-order kinetics with half-life 0.99 h equivalent to 1971.53 lux. Methylcobalamin followed pseudo-first-order kinetics upon exposure to acidic and alkaline hydrolysis with highest stability at pH 5 and least stability at pH 2. Optimization of chromatographic conditions was performed using two level full factorial design, and chromatographic analysis was executed using Inertsil column (250 × 4.6 mm, 5 μm) maintained at 25 C. Elution was carried out using 25 mM potassium dihydrogen phosphate (pH adjusted with phosphoric acid to 3.8): methanol:acetonitrile (55:35:10, v/v) as mobile phase. The flow rate was 1.0 ml/min. Detection was carried out at 220 nm using diode array detector. The method was validated as per ICH guidelines; the linearity was over concentration range 2-160 μg/ml with coefficient of determination 0.9995. The method was effectively applied for determination of methylcobalamin in Cobalvex ampoule, Cobal tablet, Cobal-F tablet, and Methyltechon oral dissolvable film without interfering from excipients within run time 6 min.

摘要

建立了一种用于测定甲钴胺的反相高效液相色谱法(RP-HPLC)。在各种条件下进行了稳定性研究。甲钴胺在酸性、碱性和光解条件下易发生水解;进一步研究了光解降解动力学和 pH 值速率分布在 pH 值 2-11 范围内。甲钴胺的光降解遵循零级动力学,半衰期为 0.99 h,相当于 1971.53 lux。甲钴胺在酸性和碱性水解条件下遵循假一级动力学,在 pH 5 时稳定性最高,在 pH 2 时稳定性最低。使用两水平完全因子设计优化了色谱条件,并使用 Inertsil 柱(250×4.6mm,5μm)在 25℃下进行色谱分析。洗脱采用 25mM 磷酸二氢钾(用磷酸调 pH 至 3.8):甲醇:乙腈(55:35:10,v/v)作为流动相。流速为 1.0ml/min。采用二极管阵列检测器在 220nm 处进行检测。该方法按照 ICH 指南进行了验证;线性范围为 2-160μg/ml,相关系数为 0.9995。该方法有效应用于测定 Cobalvex 安瓿、Cobal 片、Cobal-F 片和 Methyltechon 口服可溶膜中的甲钴胺,在 6 分钟的运行时间内,辅料无干扰。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验