Suppr超能文献

Zweymüller 型非骨水泥表面哑光假体初次全髋关节置换术后高沉降率。

High Subsidence Rate After Primary Total Hip Arthroplasty Using a Zweymüller-type Noncemented Implant With a Matte Surface.

机构信息

From the Department of Orthopedic Surgery, Kyoto University Graduate School of Medicine, Sakyo-ku, Kyoto, Japan.

出版信息

J Am Acad Orthop Surg Glob Res Rev. 2022 Jun 7;6(6). doi: 10.5435/JAAOSGlobal-D-21-00126. eCollection 2022 Jun 1.

Abstract

INTRODUCTION

The surface topography is one key factor that affects the initial fixation of prosthesis in total hip arthroplasty (THA). We aimed to evaluate the mid-term results of a Zweymüller-type noncemented femoral implant (Elance stem) that had a matte surface with a target average roughness of 1.0 to 2.5 μm. The prosthesis was subjected to alkali and heat treatments to enhance its bone-bonding property.

METHODS

In this retrospective study, 30 THAs (27 patients) done using an Elance stem from September 2012 to October 2014 were evaluated clinically and radiographically for a mean follow-up of 6.3 ± 1.7 years after the index THA.

RESULTS

Stem revision was indicated for six hips (20%). The survival rate with stem revision for any reason was 86.4% (95% confidence interval, 68.9%-94.8%) at 5 years. Stem subsidence >5 mm was noted in 17 hips (56.7%). The survival rate with stem subsidence >5 mm as the end point was 46.6% (95% confidence interval, 29.9%-64.2%) at 5 years.

CONCLUSION

The Zweymüller-type noncemented stem with a low-roughness matte surface demonstrated a high subsidence rate, although the bone-bonding property was potentially enhanced by the alkali and heat treatments. Surgeons should be aware that an insufficient surface roughness could lead to poor mechanical fixation of the noncemented stem, even with an appropriate stem geometry and surface chemistry.

摘要

简介

表面形貌是影响全髋关节置换术(THA)中假体初始固定的关键因素之一。我们旨在评估 Zweymüller 型非骨水泥股骨植入物(Elance 柄)的中期结果,该植入物具有 1.0 至 2.5μm 目标平均粗糙度的哑光表面。该假体经过碱和热处理以增强其骨结合性能。

方法

在这项回顾性研究中,对 2012 年 9 月至 2014 年 10 月期间使用 Elance 柄进行的 30 例 THA(27 例患者)进行了临床和影像学评估,在索引 THA 后平均随访 6.3±1.7 年。

结果

有 6 髋(20%)需要进行柄 revision。因任何原因进行柄 revision 的生存率为 5 年时的 86.4%(95%置信区间,68.9%-94.8%)。有 17 髋(56.7%)出现柄沉降>5mm。以柄沉降>5mm 为终点,生存率为 5 年时的 46.6%(95%置信区间,29.9%-64.2%)。

结论

尽管碱和热处理可能增强了骨结合性能,但具有低粗糙度哑光表面的 Zweymüller 型非骨水泥柄表现出较高的沉降率。外科医生应该意识到,即使具有适当的柄几何形状和表面化学性质,较低的表面粗糙度也可能导致非骨水泥柄的机械固定不良。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/bafb/9177248/c1cd1384f498/jagrr-6-e21.00126-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验