Suppr超能文献

定制基台数据叠加对种植体基台水平扫描精度的影响:一项体外研究。

Effect of custom abutment data superimposition on the accuracy of implant abutment level scanning: An in vitro study.

机构信息

Clinical Professor, Department of Prosthodontics, Gwanak Center, Seoul National University Dental Hospital, Seoul, Republic of Korea.

Professor, Department of Prosthodontics and Dental Research Institute, Seoul National University Dental Hospital, School of Dentistry, Seoul National University, Seoul, Republic of Korea.

出版信息

J Prosthet Dent. 2024 Jun;131(6):1208-1217. doi: 10.1016/j.prosdent.2022.03.008. Epub 2022 Jun 10.

Abstract

STATEMENT OF PROBLEM

When scanning implant abutments, an incomplete scan is often obtained because of a subgingival location or restricted accessibility. Whether these problems can be overcome with a novel scanning technique with digital superimposition of the custom abutment is unclear.

PURPOSE

The purpose of this in vitro study was to evaluate the effect of the process of superimposing the custom abutment library data onto the scanned abutment data on the accuracy of the digital scan with an intraoral scanner.

MATERIAL AND METHODS

A model with a single implant was prepared. The custom abutment of the corresponding implant was produced and was scanned with a laboratory scanner to produce the custom abutment library data. The custom abutment was connected to the implant, and the model was scanned with a laboratory scanner for the reference data. The custom abutment and adjacent teeth were scanned 10 times with an intraoral scanner. Thus, 10 files were saved as the first test group (IOS). After transferring 10 files of the group IOS to a computer-aided design (CAD) software program (exocad DentalCAD), the custom abutment library data were superimposed on the corresponding abutments, and the results were saved as the second test group (S-Exo). For the third test group (S-Den), the same superimposing process was performed as for the group S-Exo but by using another CAD software program (Dental System). The accuracy of the files of the 3 test groups was evaluated by comparing them with the reference file by using a 3D inspection software program. Statistical analysis was performed with 1-way repeated measures ANOVA (α=.05).

RESULTS

The RMS of the IOS group decreased significantly from 42.1 ±1.1 μm to 36.37 ±0.74 μm for the S-Exo group and 36.89 ±0.69 μm for the S-Den group after superimposition (P<.05). InTOL increased significantly from 88.17 ±0.75% to 91.57 ±0.56% in the S-Exo group and 91.31 ±0.56% in the S-Den group (P<.05). For the mean 3D discrepancy of all 66 points along the margin and 16 points of interest, the IOS group showed significantly higher discrepancy than the superimposed groups (P<.05), implying that the accuracy of scanned data with the intraoral scanner increased after superimposition with the abutment library data. No significant difference was found according to the type of software program (P>.05).

CONCLUSIONS

The process of superimposing the titanium custom abutment with the prescanned custom abutment library data improved the accuracy of a digital scan made with an intraoral scanner.

摘要

问题陈述

当扫描种植体基台时,由于基台位于龈下或可及性有限,通常无法获得完整的扫描。目前尚不清楚是否可以通过数字叠加定制基台的新技术来克服这些问题。

目的

本体外研究的目的是评估将定制基台库数据叠加到扫描基台上的过程对口腔内扫描仪数字扫描精度的影响。

材料和方法

制备单个种植体模型。制作相应种植体的定制基台并进行扫描,生成定制基台库数据。将定制基台连接到种植体上,使用实验室扫描仪对模型进行参考数据扫描。使用口腔内扫描仪扫描定制基台和相邻牙齿 10 次。因此,保存 10 个文件作为第一测试组(IOS)。将第一测试组(IOS)的 10 个文件传输到计算机辅助设计(CAD)软件程序(exocad DentalCAD)后,将定制基台库数据叠加到相应的基台上,并将结果保存为第二测试组(S-Exo)。对于第三测试组(S-Den),通过使用另一个 CAD 软件程序(Dental System)执行与组 S-Exo 相同的叠加过程。通过使用三维检测软件程序,将 3 个测试组的文件与参考文件进行比较,评估文件的准确性。采用单向重复测量方差分析(α=.05)进行统计学分析。

结果

IOS 组的 RMS 值从 42.1±1.1μm显著降低至 36.37±0.74μm(S-Exo 组)和 36.89±0.69μm(S-Den 组),叠加后(P<.05)。InTOL 从 88.17±0.75%显著增加至 91.57±0.56%(S-Exo 组)和 91.31±0.56%(S-Den 组)(P<.05)。对于沿边缘的 66 个点和 16 个感兴趣点的平均 3D 差异,IOS 组显示出明显高于叠加组的差异(P<.05),这意味着口腔内扫描仪扫描数据的准确性在与基台库数据叠加后有所提高。根据软件程序的类型,没有发现显著差异(P>.05)。

结论

将钛定制基台与预扫描定制基台库数据叠加的过程提高了口腔内扫描仪数字扫描的精度。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验