Suppr超能文献

双第二骶髂螺钉在后凸畸形患者脊柱骨盆固定中的应用。

The Utilization of Dual Second Sacral Alar-Iliac Screws for Spinopelvic Fixation in Patients with Severe Kyphoscoliosis.

机构信息

Department of Spine Surgery, Nanjing Drum Tower Hospital, The Clinical College of Nanjing Medical University, Nanjing, 210008, China.

Department of Spine Surgery, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, 210008, China.

出版信息

Orthop Surg. 2022 Jul;14(7):1457-1468. doi: 10.1111/os.13348. Epub 2022 Jun 13.

Abstract

OBJECTIVES

As a new pelvic fixation technique, the dual S2AI screws fixation technique could provide highly stable distal strength, and have wide clinical prospect in the correction of severe kyphoscoliosis. However, the ideal trajectory parameters, indications and clinical outcomes of this technique have not been reported so far. This study aimed to determine the anatomical parameters of dual S2AI screws in the normal Chinese adult population, investigating the indications of this technique and evaluating the feasibility and clinical outcomes.

METHODS

Fifteen males and 15 females with normal pelvis underwent a pelvic CT scan to determine ideal dual S2AI screws trajectories. Sagittal angle (SA), transverse angle (TA), maximal length (ML), sacral length, and skin distance were measured. Subsequently, we retrospectively reviewed the data of 16 patients (seven males and nine females) who underwent dual S2AI screw fixation and 23 patients who underwent single S2AI screw fixation between January 2014 and December 2019. Preoperative, postoperative, and latest follow-up measurements of Cobb angle, coronal balance (CB), spinal pelvic obliquity (SPO), and regional kyphosis (RK) were obtained. The mean follow-up time was 16.7 ± 7.1 months (range: 12-30 months). Independent t-test was used to determine the difference in the analysis of the trajectories. The paired sample non-parametric Wilcoxon test was performed to assess the changes in radiographic parameters between different time points and different groups.

RESULTS

For both male and females, the proximal S2AI screws had significantly higher TA and ML, but a lower SA than distal screws. Females showed significantly more caudal (SA: 25.03° ± 2.32° vs. 29.82° ± 2.47°, t = 7.742, P < 0.001) trajectories of distal screw. Additionally, ML in the females were significantly shorter than that in males (106.81 mm ± 6.79 mm vs. 101.63 mm ± 6.55 mm, t = 3.007, P = 0.003, 124.41 mm ± 7.57 mm vs. 116.23 mm ± 7.03 mm, t = 4.337, P < 0.001). Eight had unilateral and eight had bilateral dual S2AI screw placement. Respectively, both the single S2AI and dual S2AI groups showed significant postoperative improvement of Cobb angle, RK angle and SPO angle. In patients with dual S2AI screws fixation, two patients found that screws loosening occurred in one of dual screws at 1-year follow-up, and in patients with single S2AI screws fixation, six patients found screw loosing as well as two patients found screw breakage at 1-year follow-up. None of all patients had any prominent loss of correction.

CONCLUSION

The ideal trajectory of dual S2AI screw could be well established. The dual S2AI screw fixation technique is feasible in patients with severe kyphoscoliosis, and provides satisfactory correction of deformity with few postoperative complications.

摘要

目的

作为一种新的骨盆固定技术,双 S2AI 螺钉固定技术可提供高度稳定的远端强度,在严重脊柱后凸畸形的矫正中具有广阔的临床前景。然而,该技术的理想轨迹参数、适应证和临床结果尚未见报道。本研究旨在确定正常中国成年人双 S2AI 螺钉的解剖参数,探讨该技术的适应证,并评估其可行性和临床结果。

方法

15 名男性和 15 名女性进行骨盆 CT 扫描,以确定理想的双 S2AI 螺钉轨迹。测量矢状角(SA)、横角(TA)、最大长度(ML)、骶骨长度和皮肤距离。随后,我们回顾性分析了 2014 年 1 月至 2019 年 12 月期间 16 例(7 例男性和 9 例女性)接受双 S2AI 螺钉固定和 23 例接受单 S2AI 螺钉固定的患者的数据。获得 Cobb 角、冠状平衡(CB)、脊柱骨盆倾斜角(SPO)和区域后凸角(RK)的术前、术后和最新随访测量值。平均随访时间为 16.7±7.1 个月(范围:12-30 个月)。独立样本 t 检验用于分析轨迹的差异。配对样本非参数 Wilcoxon 检验用于评估不同时间点和不同组之间影像学参数的变化。

结果

对于男性和女性,近端 S2AI 螺钉的 TA 和 ML 显著较高,但 SA 较低。女性的远端螺钉轨迹明显更尾侧(SA:25.03°±2.32° vs. 29.82°±2.47°,t=7.742,P<0.001)。此外,女性的 ML 明显短于男性(106.81mm±6.79mm vs. 101.63mm±6.55mm,t=3.007,P=0.003,124.41mm±7.57mm vs. 116.23mm±7.03mm,t=4.337,P<0.001)。8 例采用单侧双 S2AI 螺钉,8 例采用双侧双 S2AI 螺钉。分别在单 S2AI 和双 S2AI 组中,术后 Cobb 角、RK 角和 SPO 角均有明显改善。在接受双 S2AI 螺钉固定的患者中,有 2 例在 1 年随访时发现其中 1 枚双螺钉出现松动,在接受单 S2AI 螺钉固定的患者中,有 6 例发现螺钉松动,2 例发现螺钉断裂。所有患者均无明显矫正丢失。

结论

双 S2AI 螺钉的理想轨迹可以很好地建立。双 S2AI 螺钉固定技术在严重脊柱后凸畸形患者中是可行的,并且具有很少的术后并发症,能提供满意的畸形矫正。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/d1eb/9251291/09ab9f242db9/OS-14-1457-g001.jpg