Institute of Livestock and Grassland Science, NARO, Nasushiobara, Tochigi, Japan.
Institute of Livestock and Grassland Science, NARO, Tsukuba, Ibaraki, Japan.
Anim Sci J. 2022 Jan-Dec;93(1):e13745. doi: 10.1111/asj.13745.
The purpose of this study was to investigate the carbon dioxide (CO ) concentration in the sampled gas to avoid low concentration of breath while measuring the methane (CH )/CO ratio using the sniffer method. This study also assessed the effect of selective elimination by applying the threshold of CO concentration to the CH /CO ratio. The gas measurement in the automatic milking system was conducted with 26 multiparous Holstein cows using an electric fan to manipulate the CO concentration in the sampled gas. Four different thresholds of the background-corrected CO concentrations (0, 0.025, 0.05, and 0.1%) were applied to every 1-s value of the individual gas measurement. Subsequently, three different upper limits of the proportion of eliminated values (none, 0.5, and 0.33) were applied to the individual records per milking. The results showed that the sampled gas must contain more than 0.1% of the corrected CO concentration to enable accurate calculation of the CH /CO ratio. It is recommended that at least half of the values in the data be larger than the threshold of the corrected CO concentration for unbiased measurement of the CH /CO ratio.
本研究旨在通过嗅探法测量甲烷(CH )/二氧化碳(CO )比值时,避免呼吸气体中 CO 浓度过低,因此对采集气体中的 CO 浓度进行了研究。本研究还评估了通过将 CO 浓度的阈值应用于 CH /CO 比值,来选择性消除气体的效果。本研究使用电扇在自动挤奶系统中对 26 头经产荷斯坦奶牛的气体进行了测量,以操纵采集气体中的 CO 浓度。将背景校正后的 CO 浓度的四个不同阈值(0、0.025、0.05 和 0.1%)应用于每个个体气体测量的 1 秒值。随后,将三个不同的消除值比例上限(无、0.5 和 0.33)应用于每次挤奶的个体记录。结果表明,采集气体必须含有超过 0.1%的校正 CO 浓度,才能准确计算 CH /CO 比值。建议至少一半的数据值要大于校正 CO 浓度的阈值,以便对 CH /CO 比值进行无偏测量。