Suppr超能文献

低植入扭矩即刻负载全颌固定义齿修复的对应咬合方案的回顾性分析。

A Retrospective Analysis of Implants with Low Insertion Torque in Immediately Loaded Full-Arch Fixed Prostheses with Corresponding Occlusal Schemes.

出版信息

Int J Oral Maxillofac Implants. 2022 May-Jun;37(3):485-493. doi: 10.11607/jomi.9274.

Abstract

PURPOSE

Poor alveolar bone quality and quantity may cause low insertion torque during implant placement; therefore, a delicate occlusal design is important for the immediate loading procedure. This retrospective clinical study aimed to investigate (1) the proportion of implants with a low insertion torque between the maxilla and mandible, (2) factors affecting implants with a low insertion torque, and (3) survival rates of implants with a low insertion torque value (< 35 Ncm) using different occlusal designs with full-arch fixed prostheses supported by immediately loaded implants.

MATERIALS AND METHODS

Between 2013 and 2017, patients who received full-arch reconstructions were treated with immediately loaded one-piece fixed prostheses supported by four to six implants. Full-arch fixed prostheses with at least one immediately loaded regular implant with a low insertion torque value were included in this study. The fixed provisional acrylic prosthesis with a rigid framework was delivered within 3 to 5 days after surgery. According to the distribution of implants with low insertion torque, provisional prostheses were divided into three groups with different occlusal schemes. Definitive prostheses were fabricated after 3 months of loading.

RESULTS

A total of 144 patients were treated; 608 and 304 regular implants were inserted in 118 maxillae and 76 mandibles, respectively. Moreover, 42 patients (11 men and 31 women) with 39 maxillae and 4 mandibles were included in this study. The proportion of implants with low insertion torque values in the maxilla was significantly greater than that in the mandible (10.5% vs 1.6%, respectively, P < .001). Implant length and low insertion torque value had no significant correlation (P = .948). Implants with a 3.3-mm diameter (narrow platform) had a greater proportion of low insertion torque values than 4-mm-wide implants (P = .002). Implants placed in a fresh socket had a greater proportion of insertion torque values ≥ 35 Ncm (P = .023). The overall cumulative implant survival rate was 98.6%. Groups 1, 2, and 3 had 14, 23, and 6 provisional prostheses, respectively. The survival rates for implants with insertion torque values < 35 Ncm and ≥ 35 Ncm were 98.4% and 98.7%, respectively, and were not significantly different (P = .866). All prostheses were still functioning during the mean follow-up of 3.7 ± 1.2 years.

CONCLUSION

The high cumulative implant survival rate indicated that implants with a low insertion torque in immediately loaded full-arch provisional prostheses did not jeopardize the outcomes after a corresponding occlusal scheme was used.

摘要

目的

种植体植入时牙槽骨质量和数量较差可能导致低植入扭矩;因此,精细的咬合设计对于即刻负载程序很重要。本回顾性临床研究旨在调查:(1)上颌和下颌植入体中低植入扭矩的比例;(2)影响低植入扭矩植入体的因素;(3)使用不同的咬合设计,用全弓固定义齿支撑即刻加载植入体,低植入扭矩值(<35 Ncm)的植入体的存活率。

材料和方法

2013 年至 2017 年间,接受全弓重建的患者接受了由四到六个植入物支撑的即刻负载一体式固定义齿治疗。本研究纳入了全弓固定义齿,其中至少有一个即刻负载的常规植入体具有低植入扭矩值。术后 3 至 5 天内,将带有刚性框架的全弓临时丙烯酸修复体交付。根据低植入扭矩植入物的分布,临时修复体分为三组,具有不同的咬合方案。在负荷 3 个月后制作最终修复体。

结果

共治疗了 144 例患者;分别在上颌骨 118 例和下颌骨 76 例中插入了 608 个和 304 个常规植入物。此外,共有 42 名患者(11 名男性和 31 名女性),其中 39 例在上颌骨,4 例在下颌骨,纳入了本研究。上颌骨低植入扭矩值的植入物比例明显高于下颌骨(分别为 10.5%和 1.6%,P<.001)。植入物长度和低植入扭矩值之间没有显著相关性(P=.948)。直径 3.3 毫米(窄平台)的植入物比 4 毫米宽的植入物具有更大的低植入扭矩值比例(P=.002)。在新鲜牙槽窝中植入的植入物具有更大的植入扭矩值≥35 Ncm 的比例(P=.023)。总的累积植入物存活率为 98.6%。组 1、2 和 3 分别有 14、23 和 6 个临时修复体。植入物扭矩值<35 Ncm 和≥35 Ncm 的存活率分别为 98.4%和 98.7%,差异无统计学意义(P=.866)。在平均 3.7±1.2 年的随访期间,所有义齿仍在使用中。

结论

高累积植入物存活率表明,在即刻负载全弓临时修复体中使用相应的咬合方案时,低植入扭矩的植入物不会影响结果。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验