Suppr超能文献

全球短缺期间碘化造影剂的保存措施:对大型医疗系统中造影剂使用的影响

Iodinated Contrast Media Conservation Measures During a Global Shortage: Effect on Contrast Media Use at a Large Health System.

作者信息

Amukotuwa Shalini A, Jackson Dana, Bammer Roland

机构信息

Department of Imaging, Monash University and Monash Health Imaging, Monash Health, Clayton, Australia 3168.

出版信息

AJR Am J Roentgenol. 2022 Dec;219(6):983. doi: 10.2214/AJR.22.28080. Epub 2022 Jun 22.

Abstract

The aim of this study was to quantify the effect of iodinated contrast media (ICM) conservation measures implemented at a single health system during a global shortage, comparing the 12-month period before intervention and the 14-day period after intervention. The mean daily utilization of contrast-enhanced CT decreased from 112 to 44 examinations, the mean ICM volume per CECT examination decreased from 88 to 74 mL, and the mean daily ICM use decreased from 9.9 to 3.3 L.

摘要

本研究的目的是量化在全球短缺期间单个卫生系统实施的碘化造影剂(ICM)保存措施的效果,比较干预前的12个月期间和干预后的14天期间。对比增强CT的日均使用量从112次检查降至44次,每次CECT检查的平均ICM用量从88毫升降至74毫升,ICM的日均使用量从9.9升降至3.3升。