Suppr超能文献

Design of a phasemeter for real-time measurements of the average plasma density with the microwave interferometer of the tokamak T-15MD.

作者信息

Drozd Alexey, Sergeev Dmitriy

机构信息

National Research Center Kurchatov Institute, Moscow 123098, Russia.

出版信息

Rev Sci Instrum. 2022 Jun 1;93(6):063501. doi: 10.1063/5.0087847.

Abstract

Interferometry is one of the key diagnostics for fusion research. This diagnostic measures electron plasma density. Interferometers that work on an intermediate frequency are widespread nowadays. The phase shift between interferometer signals has to be measured. The use of a microwave interferometer on machines, such as a tokamak, leads to challenging requirements for the phasemeter operation. We present a method to provide real-time measurements of phase shifts with values much higher than 2π. The phasemeter has been designed for the microwave interferometer of the T-15MD tokamak. It is based on microcircuits AD8302. Two signals with frequencies of 5 and 10 MHz are used as interferometer outputs. The phasemeter output will be used to create a feedback loop for the working gas injection into the tokamak chamber to control the plasma density. The phasemeter has been successfully tested. The typical phase error and non-linearity of the device are 1° and 5 × 10, respectively.