Surg Radiol Anat. 2022 Jul;44(7):991-998. doi: 10.1007/s00276-022-02968-x. Epub 2022 Jul 2.
The aim was to develop a method for reproducible orbital volume (OV) measurement in vivo based on 3D printing.
Twelve orbits were obtained from dry skulls of the Human Anatomy Department of Lille University. Computer tomography (CT) slice images of these orbits were transformed into stereo-lithography (STL) format and 3D-printed. Bone openings were closed using either putty and cellophane after printing (3D-Orb-1) or at the printing stage in silico using MeshMixer (3D-Orb-2). The results were compared with those of the conventional water-filling method as a control group (Anat-Orb).
The observers reported a mean orbital volume of 21.3 ± 2.1 cm for the open-skull method, 21.2 ± 2.4 cm for the non-sealed 3D-printing method, and 22.2 ± 2.0 cm for the closed-print method. Furthermore, the intraclass correlation coefficients (ICCs) showed excellent intra-rater agreement, i.e., an ICC of 0.994 for the first observer and 0.998 for the second, and excellent interobserver agreement (ICC: 0.969). The control and 3D-Orb-1 groups show excellent agreement (ICC: 0.972). The 3D-Orb-2 exhibits moderate agreement (ICC: 0.855) with the control and appears to overestimate orbital volume slightly.
Our 3D-printing method provides a standardized and reproducible method for the measurement of orbital volume.
旨在开发一种基于 3D 打印的可重复活体眶容积(OV)测量方法。
从里尔大学解剖学系的干颅骨中获得 12 个眼眶。对这些眼眶的计算机断层扫描(CT)切片图像进行转换,生成立体光刻(STL)格式并进行 3D 打印。打印后(3D-Orb-1)或在计算机上使用 MeshMixer 进行打印阶段(3D-Orb-2),使用油灰和玻璃纸封闭骨开口。将结果与传统的注水法(Anat-Orb)作为对照组进行比较。
观察者报告的开放式颅骨方法的平均眶容积为 21.3±2.1cm,未密封的 3D 打印方法为 21.2±2.4cm,封闭打印方法为 22.2±2.0cm。此外,组内相关系数(ICC)显示出良好的内部观察者一致性,即第一位观察者的 ICC 为 0.994,第二位观察者的 ICC 为 0.998,以及良好的观察者间一致性(ICC:0.969)。对照组和 3D-Orb-1 组显示出极好的一致性(ICC:0.972)。3D-Orb-2 与对照组显示出中等一致性(ICC:0.855),并且似乎略微高估了眶容积。
我们的 3D 打印方法为眶容积的测量提供了一种标准化且可重复的方法。