Stept L L, Flinn W R, McCarthy W J, Bartlett S T, Bergan J J, Yao J S
Arch Surg. 1987 May;122(5):599-604. doi: 10.1001/archsurg.1987.01400170105015.
Technical defects threaten the early patency of infrainguinal bypass grafts. We reviewed 849 cases of femorodistal bypass to determine the incidence of technical graft failure, as well as other causes of early graft occlusion. The efficacy of adjunctive intraoperative arteriography was assessed. Early graft failure occurred in 62 (7.3%) cases and was due to technical defects in nine (14.5%) cases. Embolization caused early failure in six (9.7%) cases, coagulation disorders caused occlusion in ten (16.1%) cases, and failure was due to inadequate runoff in seven (11.3%) cases. No identifiable cause of graft thrombosis was found in 30 (48%) cases, but thrombectomy and empiric anticoagulation therapy salvaged 25 of these grafts. Intraoperative arteriography was very specific (98%) and moderately sensitive (76%) for the detection of technical defects in this series. Technical defects appear not to be the most common cause of early infrainguinal bypass graft failure and were found in only 1% of all cases reviewed. Critical attention must be given to other causes, such as emboli, and particularly to disorders of the host coagulation system that may threaten the success of the procedure.
技术缺陷会威胁到股动脉以下旁路移植血管的早期通畅。我们回顾了849例股-远端旁路移植手术病例,以确定移植血管技术失败的发生率以及早期移植血管闭塞的其他原因。评估了术中辅助血管造影的效果。62例(7.3%)出现早期移植血管失败,其中9例(14.5%)是由于技术缺陷。栓塞导致6例(9.7%)早期失败,凝血障碍导致10例(16.1%)闭塞,7例(11.3%)失败是由于血流灌注不足。30例(48%)未发现可识别的移植血管血栓形成原因,但血栓切除术和经验性抗凝治疗挽救了其中25例移植血管。在本系列中,术中血管造影对检测技术缺陷非常特异(98%)且中度敏感(76%)。技术缺陷似乎不是股动脉以下旁路移植血管早期失败的最常见原因,在所回顾的所有病例中仅占1%。必须高度关注其他原因,如栓子,尤其是可能威胁手术成功的宿主凝血系统紊乱。