Department of Nuclear Medicine, Aalborg University Hospital, 9100 Aalborg, Denmark.
Department of Chemistry and Biochemistry, Aalborg University, 9220 Aalborg, Denmark.
Molecules. 2022 Jun 22;27(13):3997. doi: 10.3390/molecules27133997.
Technetium-99m macroaggregated albumin ([Tc]Tc-MAA) is an injectable radiopharmaceutical used in nuclear medicine for lung perfusion scintigraphy. After changing to a new batch of macroaggregated albumin (MAA), we saw unwanted uptake in the liver and spleen. The batch was therefore tested by both the supplier and us and we found it to comply with the requirements of the European Pharmacopoeia (Ph. Eur.). However, a simple comparison between the problematic batch and a batch supplied by another manufacturer showed that there was a significant difference. The quality testing showed a higher number of small particles in the problem encumbered MAA batch with unwanted in vivo uptake. In this article we present a simple method of testing for particle size of [Tc]Tc-MAA, which gives a good indication of how the radioactive drug performs in vivo. We argue that the quality control method described in the Ph. Eur. should be changed. The changes will improve concordance between the laboratory analyzes and what is seen in vivo in human lung perfusion scintigraphy. Furthermore, we hope that the MAA suppliers without delay will replace their release procedure to be in accordance with the method described in this article.
锝-99m 聚合白蛋白 ([Tc]Tc-MAA) 是一种可注射的放射性药物,用于核医学肺灌注闪烁显像。在改用新一批聚合白蛋白 (MAA) 后,我们发现肝脏和脾脏出现了不需要的摄取。因此,供应商和我们都对该批次进行了测试,发现其符合欧洲药典 (Ph. Eur.) 的要求。然而,对有问题批次和另一家制造商供应的批次进行简单比较后发现,两者之间存在显著差异。质量检测显示,问题批次的 MAA 中存在更多的小颗粒,导致体内摄取不受欢迎。在本文中,我们介绍了一种简单的 [Tc]Tc-MAA 粒径测试方法,该方法可很好地指示放射性药物在体内的性能。我们认为,Ph. Eur. 中描述的质量控制方法应该改变。这些改变将提高实验室分析与人体肺灌注闪烁显像中所见之间的一致性。此外,我们希望 MAA 供应商立即更换其放行程序,使其符合本文所述方法。