Suppr超能文献

尿路结石合并输尿管支架置入患者应用锡滤器的低剂量平扫 CT 与光谱成形技术的诊断质量比较评估。

Comparative Evaluation of Diagnostic Quality in Native Low-dose CT without and with Spectral Shaping employing a Tin Filter in Urolithiasis with implanted Ureteral Stent.

机构信息

Department of Radiology, Mechernich District Hospital, Mechernich, Germany.

Department of Radiology, University of Bonn, Germany.

出版信息

Rofo. 2022 Dec;194(12):1358-1366. doi: 10.1055/a-1856-3522. Epub 2022 Jul 18.

Abstract

PURPOSE

Spectral shaping employing a tin filter can be used for dose reduction in CT of the abdomen in patients with urolithiasis. As ureteral stents may be in direct contact with the calculus, a good image quality is mandatory. The goal of this study was to obtain data of the effect of tin filtering on image quality and dose in patients with urolithiasis in direct contact with ureteral stents.

MATERIALS AND METHODS

84 examinations (conventional low dose vs. modified low dose protocol with tin filtering, randomized) were performed in 65 patients (48 men, 17 women, age 55.0 ± 15.2 years (18-90 years), maximum of one examination per protocol). Image quality and visibility of the calculus was rated on a 5-point-Likert scale by 2 experienced radiologists. Quantitative indicators of image quality were signal-to-noise-(SNR) and contrast-to-noise-ratios (CNR) as well as a figure-of-merit (FOM).

RESULTS

With a non-inferiority margin of 0.5 points of the 5-point Likert scale, there was non-inferiority of the examinations with tin filter regarding image quality (95 % CI 4.1-4.3, rejection limit 3.5). Non-inferiority regarding visibility of the calculus could be shown (calculus size: 1-2.4 mm: 95 % CI 3.39-4.12; limit 2.73; 2.4-3.8mm: 95 % CI 4.09-4.47; limit 3.65; > 3.8mm: all maximal ratings). Average values of CNR were significantly higher using tin filters (17.0 vs. 10.6). Doses were significantly reduced in the modified protocol (effective dose 1.2 mSv vs. 1.5 mSv; size-specific dose estimate 2.33 mGy vs. 3.09 mGy) with non-significant effect in the subgroup of patients with BMI ≥ 35.

CONCLUSION

Even with direct contact between a calculus and ureteral stent, radiation reduced examinations by spectral shaping by tin filters are non-inferior to examinations without tin filtering at a concurrent significant dose reduction.

KEY POINTS

· Spectral shaping by tin filter is suitable for dose reduction.. · The image quality in patients with ureteral stents with tin filtering is non-inferior to that in a conventional low-dose protocol..

CITATION FORMAT

· Axer B, Garbe S, Hadizadeh DR. Comparative Evaluation of Diagnostic Quality in Native Low-dose CT without and with Spectral Shaping employing a Tin Filter in Urolithiasis with implanted Ureteral Stent. Fortschr Röntgenstr 2022; 194: 1358 - 1366.

摘要

目的

采用锡滤器进行光谱塑形可降低尿路结石患者 CT 腹部的剂量。由于输尿管支架可能与结石直接接触,因此需要良好的图像质量。本研究的目的是获得尿路结石直接接触输尿管支架的患者中锡过滤对图像质量和剂量影响的数据。

材料与方法

对 65 例患者(48 例男性,17 例女性,年龄 55.0±15.2 岁(18-90 岁),每个方案最多进行一次检查)进行了 84 次检查(常规低剂量与改良低剂量方案与锡过滤,随机)。两名有经验的放射科医生使用 5 分李克特量表对图像质量和结石的可视性进行评分。图像质量的定量指标包括信噪比(SNR)和对比噪声比(CNR)以及优值(FOM)。

结果

以 5 分李克特量表的 0.5 分为非劣效性边界,锡滤器检查在图像质量方面具有非劣效性(95%置信区间 4.1-4.3,拒绝界限 3.5)。可以显示结石可视性的非劣效性(结石大小:1-2.4mm:95%置信区间 3.39-4.12;限值 2.73;2.4-3.8mm:95%置信区间 4.09-4.47;限值 3.65;>3.8mm:所有最大评分)。使用锡过滤器时,CNR 的平均值显著升高(17.0 比 10.6)。改良方案中的剂量显著降低(有效剂量 1.2mSv 比 1.5mSv;体模剂量估计值 2.33mGy 比 3.09mGy),但 BMI≥35 的患者亚组中无显著影响。

结论

即使结石与输尿管支架直接接触,光谱塑形的锡滤器辐射减少检查也与无锡滤器的常规低剂量检查具有非劣效性,同时剂量显著降低。

关键词

·锡滤器光谱塑形适用于剂量降低。· 带输尿管支架的尿路结石患者使用锡过滤的图像质量与常规低剂量方案相当。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验