Suppr超能文献

[SchatzkerⅠ型胫骨平台骨折经皮螺钉固定的初步有限元分析]

[Preliminary finite element analysis of percutaneous screw fixation of Schatzker typeⅠ tibial plateau fracture].

作者信息

Wang Li

机构信息

The First Affiliated Hospital of China Medical University, Shenyang 110001, Liaoning, China.

出版信息

Zhongguo Gu Shang. 2022 Jul 25;35(7):644-9. doi: 10.12200/j.issn.1003-0034.2022.07.010.

Abstract

OBJECTIVE

To compare the stress changes and displacement of SchatzkerⅠ tibial plateau fracture screw fixation model under different loads.

METHODS

The three-dimensional CT images of the knee joint of a healthy male volunteer were selected to establish the three-dimensional model, and then the Schatzker I tibial plateau fracture model and screw fixation model were established. Simulate the two stress conditions of each model when standing on one foot and standing on two feet, the stress changes of tibia, split bone block and cannulated screw and the displacement between fractures were observed and compared.

RESULTS

When standing on both feet, the model with the largest stress value of hollow screw, split bone block and tibia was the improved triangular support fixation model group, and the model with the largest displacement in the Z-axis direction of the overall model was the conventional screw fixation model group. When standing on one foot, the model with the largest stress value of hollow screw, split bone block and tibia was the improved triangular support fixation model group, and the model with the largest displacement in the Z-axis direction of the overall model was the conventional screw fixation model group.

CONCLUSION

The lowest stress value of split bone block and screw is the palisade screw fixation model, and the largest is the improved triangular support fixation model. The Z-axis displacement of the conventional screw fixation model is the largest, and the displacement of the fence screw model is equivalent to that of the improved triangular support screw model.

摘要

目的

比较不同载荷下SchatzkerⅠ型胫骨平台骨折螺钉固定模型的应力变化及位移情况。

方法

选取一名健康男性志愿者膝关节的三维CT图像建立三维模型,进而建立SchatzkerⅠ型胫骨平台骨折模型及螺钉固定模型。模拟各模型单足站立和双足站立两种受力状态,观察并比较胫骨、劈裂骨块及空心螺钉的应力变化以及骨折间的位移情况。

结果

双足站立时,空心螺钉、劈裂骨块及胫骨应力值最大的模型为改良三角支撑固定模型组,整体模型Z轴方向位移最大的模型为传统螺钉固定模型组。单足站立时,空心螺钉、劈裂骨块及胫骨应力值最大的模型为改良三角支撑固定模型组,整体模型Z轴方向位移最大的模型为传统螺钉固定模型组。

结论

劈裂骨块及螺钉应力值最低的是栅栏式螺钉固定模型,最大的是改良三角支撑固定模型。传统螺钉固定模型的Z轴位移最大,栅栏式螺钉模型的位移与改良三角支撑螺钉模型相当。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验