Abstract

Hepatic steatosis is a common condition and an early manifestation of a systemic metabolic syndrome. As of today, there is no broadly accepted method for the diagnosis of hepatic steatosis in contrast-enhanced CT images. This retrospective study evaluates the potential of quantitative iodine values in portal venous phase iodine images in dual-energy CT (DECT) by measuring iodine concentrations in regions of interest (ROI) and analyzing the absolute iodine concentration of the liver parenchyma as well as three different blood-normalized iodine concentrations in a study cohort of 251 patients. An independent two sample t-test (p < 0.05) was used to compare the iodine concentrations of healthy and fatty liver. Diagnostic performance was assessed by ROC (receiver operating characteristic) curve analysis. The results showed significant differences between the average iodine concentration of healthy and fatty liver parenchyma for the absolute and for the blood-normalized iodine concentrations. The study concludes that the iodine uptake of the liver parenchyma is impaired by hepatic steatosis, and that the measurement of iodine concentration can provide a suitable method for the detection of hepatic steatosis in quantitative iodine images. Suitable thresholds of quantitative iodine concentration values for the diagnosis of hepatic steatosis are provided.

摘要

肝脂肪变性是一种常见的病症,也是全身代谢综合征的早期表现。目前,对比增强 CT 图像中肝脂肪变性的诊断尚无广泛接受的方法。这项回顾性研究通过测量感兴趣区域(ROI)的碘浓度,并分析肝实质的绝对碘浓度以及三种不同的血液归一化碘浓度,评估了双能 CT(DECT)门静脉期碘图像中定量碘值的潜力,该研究纳入了 251 例患者。使用独立的两样本 t 检验(p<0.05)比较了健康肝和脂肪肝的碘浓度。通过 ROC(受试者工作特征)曲线分析评估了诊断性能。结果表明,健康和脂肪肝实质的平均碘浓度在绝对碘浓度和血液归一化碘浓度方面存在显著差异。该研究得出结论,肝脂肪变性会损害肝实质的碘摄取,并且碘浓度的测量可以为定量碘图像中肝脂肪变性的检测提供一种合适的方法。为肝脂肪变性的诊断提供了合适的定量碘浓度值阈值。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/233a/9712901/3aaabb67aaaa/10278_2022_682_Fig1_HTML.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验