Galve-Huertas Andrea, Zilleruelo-Pozo Maria José, García-González Susana, Ortíz-Puigpelat Octavi, Hernández-Alfaro Federico, Aboul-Hosn Centenero Samir
Department of Oral and Maxillofacial Surgery, Universitat Internacional de Catalunya, 08017 Barcelona, Spain.
Staff Member of the Oral and Maxillofacial Surgery Department, Hospital Clinic de Barcelona, 08036 Barcelona, Spain.
Materials (Basel). 2022 Jul 19;15(14):5011. doi: 10.3390/ma15145011.
: Immediate implant placement with immediate esthetics has become a more common procedure over time, though ensuring good emergence of the axis of the implant has been a challenge. A novel macroimplant design with an angled platform (Co-Axis) has been developed to ensure exit of the head of the implant in the correct prosthetic position. A systematic literature review was carried to determine the survival rate and marginal bone loss associated with these implants. : An electronic and manual literature search was made in accordance with the PRISMA statement. The search strategy was limited to human studies, retrospective and prospective clinical trials, cross-sectional studies, and cohort studies reporting outcomes of a novel macrohybrid implant with a 12° angled implant connection. : Three articles met the inclusion criteria and were reviewed in the analysis. The estimated success rate was 95.9%. The global marginal bone loss was estimated to be -0.17 ± 0.58 mm in an environment characterized by great heterogeneity (I = 99%). The estimated mean implant stability was 69.6 ± 0.92 (ISQ). As only two studies provided the required information, it was not possible to determine publication bias. Lastly, mean recession was estimated to be practically zero (0.06 ± 0.23 mm), with great heterogeneity. : Within the limitations of this systematic review, it can be affirmed that immediate implant treatment with Co-Axis implants shows a survival rate of 95.9% at one year of follow-up, with low marginal bone loss values, near-zero soft tissue recession, and favorable papilla index values. Nevertheless, the great heterogeneity of the data requires the findings to be interpreted with caution.
随着时间的推移,即刻种植并即刻实现美学效果已成为一种更为常见的手术,不过确保种植体轴线良好穿出一直是一项挑战。一种带有倾斜平台的新型大种植体设计(共轴种植体)已被研发出来,以确保种植体头部在正确的修复位置穿出。进行了一项系统的文献综述,以确定与这些种植体相关的存活率和边缘骨吸收情况。
根据PRISMA声明进行了电子和手动文献检索。检索策略限于人类研究、回顾性和前瞻性临床试验、横断面研究以及报告新型12°倾斜种植体连接的大混合种植体结果的队列研究。
三篇文章符合纳入标准并在分析中进行了综述。估计成功率为95.9%。在异质性很大的环境中(I = 99%),总体边缘骨吸收估计为-0.17±0.58毫米。估计种植体平均稳定性为69.6±0.92(ISQ)。由于只有两项研究提供了所需信息,因此无法确定发表偏倚。最后,平均牙龈退缩估计几乎为零(0.06±0.23毫米),异质性很大。
在本系统综述的局限性范围内,可以肯定的是,使用共轴种植体的即刻种植治疗在随访一年时显示出95.9%的存活率,边缘骨吸收值低,软组织退缩接近零,乳头指数值良好。然而,数据的巨大异质性要求对研究结果进行谨慎解读。