Suppr超能文献

监测个体对训练负荷反应的夜间心率和心率变异性的可靠性和敏感性。

Reliability and Sensitivity of Nocturnal Heart Rate and Heart-Rate Variability in Monitoring Individual Responses to Training Load.

机构信息

Faculty of Sport and Health Sciences, University of Jyväskylä, Jyväskylä,Finland.

Department of Psychology, Center for Interdisciplinary Brain Research, University of Jyväskylä, Jyväskylä,Finland.

出版信息

Int J Sports Physiol Perform. 2022 Jul 6;17(8):1296-1303. doi: 10.1123/ijspp.2022-0145. Print 2022 Aug 1.

Abstract

PURPOSE

To assess the reliability of nocturnal heart rate (HR) and HR variability (HRV) and to analyze the sensitivity of these markers to maximal endurance exercise.

METHODS

Recreational runners recorded nocturnal HR and HRV on nights after 2 identical low-intensity training sessions (n = 15) and on nights before and after a 3000-m running test (n = 23). Average HR, the natural logarithm of the root mean square of successive differences (LnRMSSD), and the natural logarithm of the high-frequency power (LnHF) were analyzed from a full night (FULL), a 4-hour (4H) segment starting 30 minutes after going to sleep, and morning value (MOR) based on the endpoint of the linear fit through all 5-minute averages during the night. Differences between the nights were analyzed with a general linear model, and intraclass correlation coefficient (ICC) was used for internight reliability assessments.

RESULTS

All indices were similar between the nights followed by low-intensity training sessions. A very high ICC (P < .001) was observed in all analysis segments with a range of .97 to .98 for HR, .92 to .97 for LnRMSSD, and .91 to .96 for LnHF. HR increased (P < .001), whereas LnRMSSD (P < .01) and LnHF (P < .05) decreased after the 3000-m test compared with previous night only in 4H and FULL. Increments in HR (P < .01) and decrements in LnRMSSD (P < .05) were greater in 4H compared with FULL and MOR.

CONCLUSIONS

Nocturnal HR and HRV indices are highly reliable. Demanding maximal exercise increases HR and decreases HRV most systematically in 4H and FULL segments.

摘要

目的

评估夜间心率(HR)和心率变异性(HRV)的可靠性,并分析这些标志物对最大耐力运动的敏感性。

方法

休闲跑步者在 2 次相同低强度训练后(n=15)的夜间以及 3000 米跑步测试前后的夜间记录夜间 HR 和 HRV(n=23)。从整个夜间(FULL)、睡眠后 30 分钟开始的 4 小时(4H)段以及基于夜间所有 5 分钟平均值的线性拟合终点的早晨值(MOR)分析平均 HR、均方根差的自然对数(LnRMSSD)和高频功率的自然对数(LnHF)。使用一般线性模型分析夜间差异,并使用组内相关系数(ICC)进行夜间内可靠性评估。

结果

在低强度训练后进行的夜间,所有指标均相似。在所有分析段中均观察到非常高的 ICC(P<0.001),范围为 HR 的 0.97 至 0.98、LnRMSSD 的 0.92 至 0.97 以及 LnHF 的 0.91 至 0.96。与前一个晚上相比,3000 米测试后 HR 增加(P<0.001),而 LnRMSSD(P<0.01)和 LnHF(P<0.05)仅在 4H 和 FULL 中减少。与 FULL 和 MOR 相比,4H 中 HR 的增加(P<0.01)和 LnRMSSD 的减少(P<0.05)更大。

结论

夜间 HR 和 HRV 指数具有高度可靠性。最大强度的运动最系统地增加 4H 和 FULL 段的 HR 并降低 HRV。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验