Suppr超能文献

呼吸相可影响 CT 测量的肺静脉至肺动脉比值。

Respiratory phase can affect pulmonary vein-to-pulmonary artery ratio measured with CT.

出版信息

Am J Vet Res. 2022 Jul 25;83(10):ajvr.22.02.0026. doi: 10.2460/ajvr.22.02.0026.

Abstract

OBJECTIVE

To evaluate pulmonary vein (PV)-to-pulmonary artery (PA) ratios obtained in healthy dogs by means of various CT protocols, accounting for the effects of the respiratory phase and contrast agent used.

ANIMALS

10 healthy Beagles.

PROCEDURES

Before and after contrast medium (600 mg iodine/kg) was injected IV, thoracic CT was performed with a positive-pressure breath-hold (inspiratory phase) and at the end of expiration (expiratory phase). After CT scanning, echocardiography was performed, and an optimized right parasternal long-axis view was obtained for measurement of PV and PA diameters. The PV and PA diameters were measured subsequently for each CT protocol.

RESULTS

Mean ± SD PV:PA values obtained from pre- and postcontrast inspiratory CT were 1.058 ± 0.072 and 1.020 ± 0.053, respectively, which were comparable to the echocardiographic value (P > .05). Mean PV:PA values obtained with pre- and postcontrast expiratory CT were 1.259 ± 0.094 and 1.239 ± 0.066, respectively, which were significantly (P = .005) greater than inspiratory CT measurements. There was a significant (r > 0.5, P < .05) linear relationship between PV:PA values obtained with pre- and postcontrast inspiratory CT and echocardiography.

CLINICAL RELEVANCE

PV:PA could be measured with thoracic CT in a manner similar to that for echocardiography. However, PV:PA values measured with expiratory CT were different from previously reported values. Therefore, the respiratory phase should be considered when evaluating pulmonary vascular size through CT, and measurements with the inspiratory CT protocol would be more accurate.

摘要

目的

通过各种 CT 方案评估健康犬的肺静脉(PV)-肺动脉(PA)比值,同时考虑呼吸相和所用造影剂的影响。

动物

10 只健康比格犬。

程序

在静脉注射造影剂(600mg 碘/kg)前后,使用正压屏气(吸气相)和呼气末(呼气相)进行胸部 CT 检查。CT 扫描后进行超声心动图检查,并获得优化的胸骨旁右长轴视图,用于测量 PV 和 PA 直径。随后,为每种 CT 方案测量 PV 和 PA 直径。

结果

吸气相 CT 检查的对比前后平均±标准差 PV:PA 值分别为 1.058 ± 0.072 和 1.020 ± 0.053,与超声心动图值相当(P>.05)。呼气相 CT 检查的对比前后平均±标准差 PV:PA 值分别为 1.259 ± 0.094 和 1.239 ± 0.066,显著高于吸气相 CT 检查测量值(P=0.005)。吸气相 CT 检查前后的 PV:PA 值与超声心动图呈显著正相关(r>0.5,P<0.05)。

临床相关性

可通过 CT 以类似于超声心动图的方式测量 PV:PA。然而,呼气相 CT 测量的 PV:PA 值与先前报道的不同。因此,在通过 CT 评估肺血管大小时,应考虑呼吸相,吸气相 CT 方案的测量结果更准确。