Suppr超能文献

Descemet 膜内皮角膜移植术中移植物大小与双滚轴形成率。

Graft Size and Double Scroll Formation Rate in Descemet Membrane Endothelial Keratoplasty.

机构信息

Department of Ophthalmology, Tokyo Dental College Ichikawa General Hospital, Chiba, Japan.

Department of Ophthalmology, Okayama University, Okayama, Japan.

出版信息

Curr Eye Res. 2022 Sep;47(9):1246-1251. doi: 10.1080/02713683.2022.2104318. Epub 2022 Aug 1.

Abstract

PURPOSE

This study aimed to evaluate the usefulness of intentional double scroll formation of donor Descemet membrane (DM) inside a glass tube inserter (the Fogla technique) in DM endothelial keratoplasty (DMEK) for controlled insertion and unfolding of grafts.

METHODS

Eleven consecutive patients who underwent DMEK were included in this study. We sought to specify graft characteristics in which double scroll configuration was successfully formed using the Fogla technique. We compared donor age, graft size, surgical time, unfolding time, and visual outcomes between patients with and without double scroll configuration. The ability to form double scroll formation of DM grafts of various diameters and unfolding time of DM grafts was evaluated using total seven eye-bank eyes in experiments.

RESULTS

A double scroll configuration inside a glass tube was successfully obtained in six DMEK grafts (54.5%). When comparing clinical features between those with and without double scroll configuration, only graft size was significantly larger in those with double scroll configuration (7.9 ± 0.2 mm) than in those without (7.4 ± 0.4,  = 0.03). There were no significant differences in other features and clinical outcomes, although unfolding-time was shorter in eyes with double scroll configuration (4.6 ± 2.0 min) compared to those without (8.6 ± 8.1,  = 0.21). experiments showed that unfolding time was significantly shorter in double scroll configuration (2.71 ± 0.49 min) than in single scroll (5.02 ± 0.79,  = 0.01).

CONCLUSIONS

A double scroll configuration within a glass tube can be obtained more frequently in larger DMEK grafts (8.0 mm in diameter), which may result in easier and faster DMEK procedures.

摘要

目的

本研究旨在评估玻璃管插管器内供体后弹力层(Descemet 膜,DM)的有意双螺旋形成( Fogla 技术)在 DM 内皮角膜移植术(DMEK)中的作用,以实现移植物的受控插入和展开。

方法

本研究纳入了 11 例连续接受 DMEK 的患者。我们试图明确使用 Fogla 技术成功形成双螺旋构型的移植物特征。我们比较了有和无双螺旋构型患者的供体年龄、移植物大小、手术时间、展开时间和视力结果。在实验中,使用总共 7 只眼库眼评估了各种直径 DM 移植物的双螺旋形成能力和 DM 移植物的展开时间。

结果

在 6 例 DMEK 移植物中(54.5%)成功获得玻璃管内的双螺旋构型。在比较有和无双螺旋构型的临床特征时,只有双螺旋构型的移植物大小明显大于无双螺旋构型(7.9±0.2mm 对 7.4±0.4mm,=0.03)。尽管双螺旋构型的展开时间更短(4.6±2.0min),但在其他特征和临床结果方面无显著差异(无双螺旋构型为 8.6±8.1min,=0.21)。实验表明,双螺旋构型的展开时间明显短于单螺旋构型(2.71±0.49min 对 5.02±0.79min,=0.01)。

结论

在较大的 DMEK 移植物(直径 8.0mm)中,玻璃管内更容易形成双螺旋构型,这可能使 DMEK 手术更简单、更快。