慢性主动脉瓣反流患者静息和运动时左心室射血分数及容积的可重复性

Reproducibility of rest and exercise left ventricular ejection fraction and volumes in chronic aortic regurgitation.

作者信息

Cornyn J W, Massie B M, Greenberg B, Loge D L, Thomas D, Bristow J D, Cheitlin M, Krishnamurthy G

出版信息

Am J Cardiol. 1987 Jun 1;59(15):1361-5. doi: 10.1016/0002-9149(87)90920-9.

Abstract

To assess the variability of rest and exercise radionuclide ventriculography in patients with aortic regurgitation (AR), 22 patients in stable condition with chronic AR underwent radionuclide ventriculography at rest and during exercise for measurement of left ventricular volumes and ejection fraction (EF) on 2 occasions 3 months apart. For the group, there were no significant differences between the findings of the 2 studies except for a slightly lower exercise end-systolic volume on the second study. The inter-study differences and variabilities (expressed as the standard deviation of differences) for rest and exercise EF and change in EF were 0 +/- 0.04, +0.02 +/- 0.05 and +0.01 +/- 0.05, respectively. Thus, although mean differences were minor, considerable individual variability occurred, the magnitude of which was similar to that reported for other patient populations. In 3 patients who had an initial normal response to exercise (increase in EF greater than or equal to 0.05), the response became abnormal and in 2 who initially had an abnormal response, the response normalized. This variability must be considered in clinical decision-making or in research study design for patients with chronic AR.

摘要

为评估主动脉瓣关闭不全(AR)患者静息和运动时放射性核素心室造影的变异性,22例病情稳定的慢性AR患者在静息和运动时接受放射性核素心室造影,分别于相隔3个月的2个时间点测量左心室容积和射血分数(EF)。对于该组患者,除第二次检查时运动末期收缩容积略低外,两项研究结果之间无显著差异。静息和运动时EF以及EF变化的研究间差异和变异性(以差异标准差表示)分别为0±0.04、+0.02±0.05和+0.01±0.05。因此,尽管平均差异较小,但个体间存在相当大的变异性,其幅度与其他患者群体报道的相似。在3例最初运动反应正常(EF增加大于或等于0.05)的患者中,反应变为异常;在2例最初反应异常的患者中,反应恢复正常。对于慢性AR患者,在临床决策或研究设计中必须考虑这种变异性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验