Dai Fanfan, Chen Si, Feng Tingting, Lu Wenhsuan, Chen Gui, Jiang Jiuhui, Jiang Ruoping, Lin Jiuxiang, Han Bing, Xu Tianmin
Second Clinical Division, Peking University School and Hospital of Stomatology, Beijing, China.
National Clinical Research Center for Oral Diseases and National Engineering Laboratory for Digital and Material Technology of Stomatology and Beijing Key Laboratory of Digital Stomatology, Beijing, China.
Odontology. 2023 Jan;111(1):238-247. doi: 10.1007/s10266-022-00732-6. Epub 2022 Aug 9.
This study proposes a method that integrates maxillary dental cast and cephalograms and evaluates its accuracy compared with cone-beam computed tomography (CBCT) scans. The study sample comprised 20 adult patients with records of dental casts, cephalograms, and craniofacial CBCT scans. The maxillary dental cast was integrated with lateral and frontal cephalograms based on best-fit registration of palatal and dental outline curves from dental cast with cephalogram tracings. Linear measurement was conducted to assess the intra- and inter-examiner reproducibility of the proposed integration method using intraclass correlation coefficients; linear and angular measurements were conducted to assess its accuracy with CBCT scans as a standard reference. Paired t test, one sample t test, and mean ± standard deviation of the absolute value of difference were used to compare the integrated images and CBCT. The integration method showed good intra- and inter-examiner reproducibility (intraclass correlation coefficients > 0.98). The differences in linear and angular measurements between the integrated images and CBCT were not statistically significant but with a large deviation. When absolute value of difference was computed, the linear distance error was 0.51 ± 0.34 mm, the tooth point coordinate errors in X, Y and Z axes were 0.22 ± 0.22, 0.38 ± 0.32 and 0.21 ± 0.21 mm, respectively; the angular error in pitch, roll and yaw of the dental cast was 0.82 ± 0.51, 0.92 ± 0.59 and 0.80 ± 0.41 degree, respectively. The proposed method for integration of dental cast and cephalograms showed good reproducibility and acceptable accuracy compared with CBCT. It could be helpful for researchers to study three-dimensional tooth growth changes using the existing craniofacial growth data especially cephalograms.
本研究提出了一种将上颌牙模与头颅侧位片相结合的方法,并与锥形束计算机断层扫描(CBCT)进行比较,评估其准确性。研究样本包括20名成年患者,他们有牙模、头颅侧位片和颅面部CBCT扫描记录。基于牙模上腭和牙齿轮廓曲线与头颅侧位片描迹的最佳拟合配准,将上颌牙模与头颅侧位片和正位片相结合。使用组内相关系数进行线性测量,以评估所提出的整合方法在检查者内和检查者间的可重复性;以CBCT扫描作为标准参考进行线性和角度测量,以评估其准确性。采用配对t检验、单样本t检验以及差值绝对值的均值±标准差来比较整合图像和CBCT。该整合方法在检查者内和检查者间均显示出良好的可重复性(组内相关系数>0.98)。整合图像与CBCT之间的线性和角度测量差异无统计学意义,但偏差较大。计算差值绝对值时,线性距离误差为0.51±0.34mm,牙齿点在X、Y和Z轴上的坐标误差分别为0.22±0.22、0.38±0.32和0.21±0.21mm;牙模在俯仰、横滚和偏航方向的角度误差分别为0.82±0.51、0.92±0.59和0.80±0.41度。与CBCT相比,所提出的牙模与头颅侧位片整合方法显示出良好的可重复性和可接受的准确性。这可能有助于研究人员利用现有的颅面部生长数据,尤其是头颅侧位片,来研究三维牙齿生长变化。