Suppr超能文献

腰椎融合术后,采用 Hounsfield 单位测量相邻节段椎体骨密度的变化。

Adjacent Segment Vertebral Body Bone Density Changes as Measured By Hounsfield Units After Lumbar Spine Fusion.

机构信息

Department of Neurosurgery, University of California, San Francisco, California, USA.

Department of Neurosurgery, University of California, San Francisco, California, USA.

出版信息

World Neurosurg. 2022 Nov;167:e464-e468. doi: 10.1016/j.wneu.2022.08.033. Epub 2022 Aug 12.

Abstract

OBJECTIVE

We sought to evaluate Hounsfield units (HU) at the adjacent segment after single-level transforaminal lumbar interbody fusion (TLIF) with preoperative and postoperative computed tomography scans.

METHODS

We performed a retrospective study on a series of patients who underwent L4-5 TLIF, from 2007 to 2017, by 3 spine surgeons at our institution. One-hundred and forty-three total patients were identified, and 41 patients with minimum 1-year follow-up met inclusion criteria. HU values were measured on preoperative and postoperative computed tomography at the adjacent L3 segment and at L1 as a control arm. Lumbar lordosis, pelvic tilt, pelvic incidence, sacral slope, and sagittal vertical axis were also collected preoperatively and postoperatively.

RESULTS

Mean preoperative HU value at L3 did not differ from the postoperative value (134.11 ± 47.14 mg/cm vs. 141.21 ± 55.14 mg/cm, P = 0.34). Similarly, the mean preoperative HU value at the L1 control level region of interest did not differ from the postoperative value (150.17 ± 53.91 mg/cm vs. 145.78 ± 58.34 mg/cm, P = 0.634). The interrater reliability of HU measurements was satisfactory with a resulting intraclass correlation coefficient of 0.76.

CONCLUSIONS

As measured by HU, we did not observe a change in bone density or other signs of adjacent segment disease at the L3 vertebral body 12 months after L4-5 TLIF. Spinopelvic parameters were not shown to be correlated with HU changes.

摘要

目的

我们试图通过术前和术后计算机断层扫描评估单节段经椎间孔腰椎体间融合(TLIF)后相邻节段的体素值(HU)。

方法

我们对 2007 年至 2017 年期间在我们机构由 3 位脊柱外科医生进行的 L4-5TLIF 的一系列患者进行了回顾性研究。共确定了 143 名患者,其中 41 名患者在随访至少 1 年后符合纳入标准。在术前和术后 CT 上测量相邻 L3 节段和 L1 段(作为对照臂)的 HU 值。还收集了术前和术后腰椎前凸角、骨盆倾斜角、骨盆入射角、骶骨倾斜角和矢状垂直轴。

结果

L3 节段术前 HU 值与术后 HU 值无差异(134.11 ± 47.14mg/cm 与 141.21 ± 55.14mg/cm,P=0.34)。同样,术前 L1 对照组 ROI 的 HU 值与术后 HU 值无差异(150.17 ± 53.91mg/cm 与 145.78 ± 58.34mg/cm,P=0.634)。HU 测量的组内相关系数为 0.76,提示观察者间的可靠性良好。

结论

根据 HU 测量,我们未发现 L4-5TLIF 后 12 个月 L3 椎体的骨密度或其他相邻节段疾病的变化。脊柱骨盆参数与 HU 变化无关。