Labuneț Anca, Objelean Adriana, Almășan Oana, Kui Andreea, Buduru Smaranda, Sava Sorina
Prosthetic Dentistry and Dental Materials Department, Iuliu Hațieganu University of Medicine and Pharmacy, 31 Avram Iancu Street, 400083 Cluj-Napoca, Romania.
Prosthetic Dentistry and Dental Materials Department, Iuliu Hațieganu University of Medicine and Pharmacy, 32 Clinicilor Street, 400006 Cluj-Napoca, Romania.
Dent J (Basel). 2022 Aug 1;10(8):141. doi: 10.3390/dj10080141.
Fixed retainers assist in maintaining the outcomes of orthodontic treatment. Fixed retention may be affected by bruxism.
Evaluate two adhesives (an ormocer and a flowable composite) used for fixed orthodontic retention in simulated bruxism settings, compared to regular mastication, using a dual axis chewing simulator.
Eighty human teeth were used. Periodontal tissues were simulated and exposed to 120,000 mechanical cycles, corresponding to 6 months of clinical service. Each set of two teeth was supplied with a pre-shaped, fixed, multi-braided, stainless steel wire retainer, in 1.5 cm portions, to establish passive contact with the lingual surface of the teeth. The Adhesive Remnant Index (ARI) was used to evaluate the shear bond strength. A stereomicroscope was used to assess the micro-infiltration.
There was no significant difference in the mean value of micro-infiltration between adhesives in the mastication group but in the bruxism group. During testing, one composite sample (ARI score 1) was broken in the mastication group, while three ormocer samples (ARI score 2) and one composite sample (ARI score 1) were broken in the bruxism group.
The mean value for micro-infiltration in composite (0.31) was more than double that in ormocer (0.13).
固定保持器有助于维持正畸治疗效果。固定保持可能会受到磨牙症的影响。
使用双轴咀嚼模拟器,评估两种用于模拟磨牙症环境下固定正畸保持的黏合剂(一种有机陶瓷和一种流动树脂复合材料),并与正常咀嚼情况进行比较。
使用80颗人牙。模拟牙周组织并使其经受120,000次机械循环,相当于6个月的临床使用。每组两颗牙配备一段预先塑形的、固定的、多股编织不锈钢丝保持器,长度为1.5厘米,以与牙齿舌面建立被动接触。使用黏合剂残留指数(ARI)评估剪切粘结强度。使用体视显微镜评估微渗入情况。
在咀嚼组中,黏合剂之间的微渗入平均值无显著差异,但在磨牙症组中有差异。测试期间,咀嚼组中有一个树脂复合材料样本(ARI评分为1)断裂,而磨牙症组中有三个有机陶瓷样本(ARI评分为2)和一个树脂复合材料样本(ARI评分为1)断裂。
树脂复合材料的微渗入平均值(0.31)是有机陶瓷(0.13)的两倍多。