A review of human parathyroid hormone measurements is presented. Although parathyroid hormone was among the first hormones to be measured with the radioimmunoassay technique in 1963, there are even now still many pitfalls in both the technical aspects and clinical applicability of this assay. The main reasons for these difficulties are presented: firstly the complex intra- and extraglandular metabolism of parathyroid hormone results in the heterogeneity of the hormone in serum; secondly, the scarceness of pure human parathyroid hormone delays the development of a complete homologous human assay. The existing assays however have, despite their limitations, enormously contributed to our knowledge of parathyroid hormone secretion in both the normal state and in disease. The clinical applicability of these assays is reviewed and future technical improvements are suggested.
本文对人体甲状旁腺激素检测进行了综述。尽管甲状旁腺激素是1963年最早采用放射免疫分析技术进行检测的激素之一,但即便在当下,该检测在技术层面和临床应用方面仍存在诸多缺陷。文中阐述了产生这些困难的主要原因:其一,甲状旁腺激素在腺体内外的复杂代谢导致其在血清中的异质性;其二,纯人甲状旁腺激素的稀缺延缓了完整同源性人体检测方法的开发。然而,现有检测方法尽管存在局限性,但极大地增进了我们对甲状旁腺激素在正常状态和疾病状态下分泌情况的了解。本文对这些检测方法的临床应用进行了综述,并提出了未来技术改进的建议。