Angle Orthod. 2022 Nov 1;92(6):714-721. doi: 10.2319/031522-220.1.
To analyze the accuracy of planned tooth movements of torque, tip, rotations, and transverse width values with lingual straight-wire technique.
40 Caucasian subjects with mean age of 23.9 years, consecutively treated in private practice with a lingual straight-wire appliance (STb, Ormco, Glendora, Calif) were evaluated. Maxillary and mandibular dental casts were taken before treatment (T0), in the setup (T1), and at the end of treatment (T2) and scanned with an intraoral 3D scanner Carestream CS 3600 (Carestream Dental, Atlanta, GA). Virtual models at the three time points were superimposed on T1 using 3D software, and the coordinates were exported as a set of x, y, and z values. Angular and linear measurements were analyzed to measure torque, tip, rotation movements, and transverse intra-arch widths. Changes among the three time points were analyzed with Friedman's nonparametric test.
A general increase in torque was recorded in the setup and in the final result, except for the maxillary molars. Torque, tip, and rotation movement mean accuracy was ≥84% for incisors, canines, and premolars. A general increase in transverse width was measured in the setup and in the final models, except for the upper second molars, which showed reduced transverse width during treatment.
The movements planned in the setup to obtain the ideal torque, tip, and rotations actually occurred, except for second molars, which showed less accuracy. Planned expansion of the arches occurred only partially.
分析舌侧直丝弓技术中转矩、倾斜、旋转和横向宽度值的计划牙移动的准确性。
评估 40 名平均年龄为 23.9 岁的白种人患者,他们在私人诊所中连续接受舌侧直丝弓矫治器(STb,Ormco,Glendora,加利福尼亚州)治疗。在治疗前(T0)、设置阶段(T1)和治疗结束时(T2)拍摄上颌和下颌牙模型,并使用口腔内 3D 扫描仪 Carestream CS 3600(Carestream Dental,亚特兰大,佐治亚州)进行扫描。使用 3D 软件将三个时间点的虚拟模型与 T1 叠加,并将坐标导出为一组 x、y 和 z 值。分析角度和线性测量以测量转矩、倾斜、旋转运动和横向弓内宽度。使用 Friedman 非参数检验分析三个时间点之间的变化。
在设置和最终结果中记录了转矩的普遍增加,上颌磨牙除外。切牙、尖牙和前磨牙的转矩、倾斜和旋转运动的平均准确性≥84%。在设置和最终模型中测量到横向宽度的普遍增加,上颌第二磨牙除外,上颌第二磨牙在治疗过程中显示出横向宽度减小。
在设置中计划获得理想转矩、倾斜和旋转的运动实际上发生了,上颌第二磨牙除外,上颌第二磨牙的准确性较低。弓的扩张计划仅部分发生。