用于确定运动强度的腕戴式可穿戴设备的准确性。

Accuracy of wrist-worn wearable devices for determining exercise intensity.

作者信息

Ho Wei-Te, Yang Yi-Jen, Li Tung-Chou

机构信息

Department of Physical Medicine and Rehabilitation, Cathay General Hospital, Taipei.

Department of Physical Medicine and Rehabilitation, National Taiwan University Hospital.

出版信息

Digit Health. 2022 Sep 4;8:20552076221124393. doi: 10.1177/20552076221124393. eCollection 2022 Jan-Dec.

Abstract

OBJECTIVE

As an indicator of exercise intensity, heart rate can be measured in a timely manner using wrist-worn devices. No study has attempted to estimate a target exercise intensity using wearable devices. The objective of the study was to evaluate the validity of prescribing exercise intensity using wrist-worn devices.

METHODS

Thirty healthy subjects completed a maximal cardiopulmonary exercise test. Their heart rates were recorded using an electrocardiogram and two devices-Apple Watch Series 6 and Garmin Forerunner 945. Exercise intensity with the target heart rate was defined as resting heart rate + (maximal heart rate - resting heart rate) *% (%: 40-60% for moderate-intensity exercise and 60-89% for vigorous-intensity exercise). Heart rate was analyzed at the lower and upper limits of each exercise intensity (HR40, HR60, and HR89). The mean absolute percentage error and concordance correlation coefficient were calculated, and Bland-Altman plots and scatterplots were constructed.

RESULTS

Both devices showed a low mean absolute error (1.16-1.48 bpm for Apple and 1.35-2.25 for Garmin) and mean absolute percentage error (<1% for Apple and 1.16-1.39% for Garmin) in all intensities. A substantial correlation with electrocardiogram-measured heart rate was observed for moderate to vigorous intensity with concordance correlation coefficient > 0.95 for both devices, except that Garmin showed moderate correlation at the upper limit of vigorous activity with concordance correlation coefficient = 0.936. Moreover, Bland-Altman plots and scatterplots demonstrated a strong correlation without systematic error when the values obtained via the two devices were compared with electrocardiogram measurements.

CONCLUSIONS

Our findings indicate the high validity of exercise prescriptions based on the heart rate measured by the two devices. Additional research should explore other populations to confirm these findings.

摘要

目的

心率作为运动强度的指标,可通过腕戴式设备及时测量。尚无研究尝试使用可穿戴设备来估计目标运动强度。本研究的目的是评估使用腕戴式设备规定运动强度的有效性。

方法

30名健康受试者完成了最大心肺运动试验。使用心电图以及两款设备——苹果手表Series 6和佳明Forerunner 945记录他们的心率。目标心率对应的运动强度定义为静息心率 +(最大心率 - 静息心率)×百分比(百分比:中等强度运动为40 - 60%,高强度运动为60 - 89%)。在每种运动强度的下限和上限(HR40、HR60和HR89)处分析心率。计算平均绝对百分比误差和一致性相关系数,并绘制Bland - Altman图和散点图。

结果

两款设备在所有强度下均显示出较低的平均绝对误差(苹果为1.16 - 1.48次/分钟,佳明为1.35 - 2.25次/分钟)和平均绝对百分比误差(苹果小于1%,佳明为1.16 - 1.39%)。对于中等至高强度运动,两款设备与心电图测量的心率均存在显著相关性,一致性相关系数均>0.95,但佳明在高强度活动上限处显示为中等相关性,一致性相关系数 = 0.936。此外,当将通过两款设备获得的值与心电图测量值进行比较时,Bland - Altman图和散点图显示出很强的相关性且无系统误差。

结论

我们的研究结果表明基于这两款设备测量的心率制定运动处方具有很高的有效性。后续研究应探索其他人群以证实这些发现。