Department of Oto-Rhino-Laryngology and Head and Neck Surgery, Lucerne Cantonal Hospital, Switzerland.
Faculty of Health Sciences and Medicine, University of Lucerne, Switzerland.
J Laryngol Otol. 2023 Aug;137(8):851-865. doi: 10.1017/S0022215122002183. Epub 2022 Sep 28.
To assess hearing rehabilitation in patients with congenital aural atresia using an active middle-ear implant (Vibrant Soundbridge).
Of a cohort of 70 microtia and atresia patients, 10 underwent Vibrant Soundbridge implantation between 2008 and 2021. Two of the 10 patients had binaural implantation, resulting in 12 ears for analysis. Pre- and post-operative audiometry data were analysed, and patient satisfaction was evaluated. Surgical issues regarding coupling sites and outcomes were analysed.
Pure tone average (0.5, 1, 2 and 4 kHz) improved from a pre-operative mean (standard deviation) of 65.3 (8.7) dB HL to a post-operative mean of 26.8 (4.9) dB HL. This resulted in a mean pure tone average gain of 38.5 dB HL. The results indicate no obvious difference between stapes ( = 8) and incus ( = 4) coupling. The mean effective gain for 0.5, 1, 2 and 4 kHz was -17.8 dB HL (standard deviation = 4.3). Concerning effective gain, Vibrant Soundbridge performed best at 2 kHz. Patients reported high overall satisfaction, good sound quality and strongly improved directional hearing.
An active middle-ear implant (Vibrant Soundbridge) allows hearing rehabilitation in selected atretic ears, and provides long-term hearing stability in children and adults.
使用主动中耳植入物(Vibrant Soundbridge)评估先天性听小骨畸形患者的听力康复情况。
在 70 例小耳畸形和闭锁患者中,有 10 例于 2008 年至 2021 年期间接受了 Vibrant Soundbridge 植入。其中 2 例患者双耳植入,共 12 只耳朵进行分析。分析了术前和术后的听力测量数据,并评估了患者的满意度。分析了耦合部位和结果的手术问题。
纯音平均(0.5、1、2 和 4 kHz)从术前平均(标准差)65.3(8.7)dB HL 提高到术后平均 26.8(4.9)dB HL。这导致纯音平均增益平均为 38.5 dB HL。结果表明,镫骨( = 8)和砧骨( = 4)耦合之间没有明显差异。0.5、1、2 和 4 kHz 的平均有效增益为-17.8 dB HL(标准差= 4.3)。就有效增益而言,Vibrant Soundbridge 在 2 kHz 时表现最佳。患者报告总体满意度高、音质好、定向听力明显改善。
主动中耳植入物(Vibrant Soundbridge)可使选定的闭锁耳恢复听力,并为儿童和成人提供长期听力稳定性。