Sharma Manoj, Sharma Bimla, Gupta Manish, Panday Bhuwan Chand, Sahai Chand, Sood Jayashree
Institute of Anaesthesiology, Pain and Perioperative Medicine, Sir Ganga Ram Hospital, Old Rajinder Nagar, New Delhi, India.
J Anaesthesiol Clin Pharmacol. 2022 Apr-Jun;38(2):221-227. doi: 10.4103/joacp.JOACP_465_20. Epub 2021 Nov 18.
The LMA® ProSeal™, LMA® Supreme™ and Ambu® AuraGain™ are second-generation supraglottic airway devices (SADs) with integrated gastric access. In this study, we compared the clinical performance of these three devices in adults for controlled ventilation in anesthetized paralysed patients.
Two hundred and seventy adults, American Society of Anesthesiologists (ASA) Physical Status I-III, undergoing elective surgical procedures, were randomized into three groups with 90 patients in each: Group 1: LMA® ProSeal™, Group 2: LMA® Supreme™ and Group 3: Ambu® AuraGain™. All the three devices were evaluated for oropharyngeal seal pressure (OSP) and other parameters: ease and the number of attempts at device placement, fibreoptic laryngeal view and intraoperative and postoperative complications.
In the present study, the mean OSP was 38.9 ± 3.050 cm HO in the LMA ProSeal™ group, 37.41 ± 4.097 cm HO in LMA® Supreme™ group and 37.32 ± 3.740 cm HO in Ambu® AuraGain™ group. The difference was found to be statistically significant (P = 0.006). The three groups were comparable for the ease of device insertion, number of attempts at device placement, fibreoptic laryngeal view, intraoperative and postoperative complications.
In this study, we found that the LMA® ProSeal™ provided the highest OSP in comparison to the other two devices, even though this difference is not clinically relevant. The use of Ambu® AuraGain™ was associated with difficult and lowest first-time insertion success rate (P < 0.001) along with an increased incidence of airway trauma as compared to the other two SADs.
LMA® ProSeal™、LMA® Supreme™和Ambu® AuraGain™是具有集成胃通路的第二代声门上气道装置(SADs)。在本研究中,我们比较了这三种装置在成年麻醉瘫痪患者控制通气中的临床性能。
270例美国麻醉医师协会(ASA)身体状况I - III级的成年患者,接受择期外科手术,被随机分为三组,每组90例:第1组:LMA® ProSeal™,第2组:LMA® Supreme™,第3组:Ambu® AuraGain™。对所有三种装置评估口咽密封压(OSP)及其他参数:装置放置的难易程度和尝试次数、纤维喉镜视野以及术中和术后并发症。
在本研究中,LMA ProSeal™组的平均OSP为38.9 ± 3.050 cm HO,LMA® Supreme™组为37.41 ± 4.097 cm HO,Ambu® AuraGain™组为37.32 ± 3.740 cm HO。发现差异具有统计学意义(P = 0.006)。三组在装置插入的难易程度、装置放置的尝试次数、纤维喉镜视野、术中和术后并发症方面具有可比性。
在本研究中,我们发现与其他两种装置相比,LMA® ProSeal™提供了最高的OSP,尽管这种差异在临床上并不相关。与其他两种SADs相比,使用Ambu® AuraGain™与首次插入困难及成功率最低(P < 0.001)相关,且气道创伤发生率增加。