Suppr超能文献

评估一种新型肝素-前列环素基抗血栓形成配方血液采集管的临床应用。

Evaluation of a novel heparin-iloprost-based antithrombotic formulation blood collection tube for clinical usage.

机构信息

Department of Clinical Biochemistry, North Zealand Hospital, University of Copenhagen, Denmark.

Department of Clinical Biochemistry, North Zealand Hospital, University of Copenhagen, Denmark.

出版信息

Clin Chim Acta. 2022 Dec 1;537:87-95. doi: 10.1016/j.cca.2022.10.006. Epub 2022 Oct 21.

Abstract

BACKGROUND

The objective of our study was to evaluate a single blood collection tube with a novel antithrombotic formulation to measure both hematological, biochemical, and d-dimer analytes.

METHODS

Paired samples of gold standard blood tubes (EDTA, lithium heparin, sodium citrate) and a new antithrombotic formulation blood tube were collected from 187 patients. The new antithrombotic tube is a lithium heparin tube preloaded with a liquid form of prostacyclin analog. The novel tube was tested on seventeen hematological parameters and smears against EDTA, on fourteen biochemical parameters against lithium heparin and on d-dimer against sodium citrate.

RESULTS

All correlation coefficients were close to 0.99. The Bland-Altman analyses presented a satisfactory correspondence for all analytes. All the hematological examinations demonstrated comparable results between EDTA and the novel formulation, except for platelet counts analyzed by impedance method, but not by fluorescence. We detected lower mean platelet volume with/without outliers (5.06%)/(5.13%) in the novel formulation and increased mean corpuscular hemoglobin concentration (2.55%). All the biochemistry analytes demonstrated comparable results between lithium heparin and the novel tube. d-dimer showed comparable results between citrated blood and the novel formulation after dilution correction.

CONCLUSIONS

We describe a novel antithrombotic formulation tube with the potential to be introduced into clinical laboratories for simultaneous analysis of thirty-two blood analytes.

摘要

背景

我们研究的目的是评估一种新型抗凝血配方的单采血液采集管,以测量血液学、生化和 D-二聚体分析物。

方法

从 187 名患者中采集了金标准血液管(EDTA、肝素锂、柠檬酸钠)和新型抗凝血配方血液管的配对样本。新型抗凝血管是一种预先加载液体形式前列环素类似物的肝素锂管。该新型管在 17 个血液学参数和涂片上与 EDTA 进行了测试,在 14 个生化参数上与肝素锂进行了测试,在 D-二聚体上与柠檬酸钠进行了测试。

结果

所有相关系数均接近 0.99。Bland-Altman 分析对于所有分析物都呈现出令人满意的对应关系。除了阻抗法分析的血小板计数外,所有血液学检查在 EDTA 和新型配方之间均表现出可比的结果,但荧光法除外。我们检测到新型配方的血小板平均体积(有/无异常值)分别为 5.06%/5.13%,平均红细胞血红蛋白浓度升高(2.55%)。所有生化分析物在肝素锂和新型管之间都表现出可比的结果。经稀释校正后,D-二聚体在柠檬酸化血液和新型配方之间显示出可比的结果。

结论

我们描述了一种新型抗凝血配方管,具有引入临床实验室同时分析 32 种血液分析物的潜力。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验