Sci Rep. 2022 Nov 8;12(1):18969. doi: 10.1038/s41598-022-23519-9.
Carbon-fiber (CF) plates are a promising alternative to metal plates. However, reported experience in orthopaedic oncology remains limited. The aim of this study was to identify complications of patients with bone tumors treated with CF plates. Between February 2015 and May 2021, 13 centers retrospectively registered patients with bone tumors that were reconstructed using CF plates. Complications were identified, and timing and etiology of complications were noted. Similar complications were tabulated and classified based on mechanical, non-mechanical and paediatric complications. Mechanical complications included: (1) aseptic loosening or graft-host non-union, and (2) structural complications. Non-mechanical complications included: (3) soft tissue complications, (4) infection and (5) tumor progression. Specific paediatric complications included (6) growth arrest resulting in longitudinal or angular deformity. Ninety-six patients were included with a median follow-up time of 35 months. In total, 22 (23%) patients had complications. Mechanical complications included: 1 (1%) aseptic loosening, 2 (2%) non-unions, and 7 (7%) structural complications. Non-mechanical complications included 1 (1%) soft tissue complication, 4 (4%) infections and 5 (5%) tumor progressions. Paediatric complications occurred in 2 (2%) patients. This study suggests CF plates are safe to use in demanding reconstructions after bone tumor resections, presenting a seemingly low complication profile.
碳纤维(CF)板是金属板的一种有前途的替代品。然而,骨科肿瘤学的报告经验仍然有限。本研究的目的是确定使用 CF 板治疗骨肿瘤患者的并发症。2015 年 2 月至 2021 年 5 月,13 个中心回顾性登记了使用 CF 板重建的骨肿瘤患者。确定了并发症,并记录了并发症的时间和病因。根据机械性、非机械性和儿科并发症对类似的并发症进行了制表和分类。机械性并发症包括:(1)无菌性松动或移植物-宿主不愈合,和(2)结构并发症。非机械性并发症包括:(3)软组织并发症,(4)感染和(5)肿瘤进展。特定的儿科并发症包括(6)生长停滞导致的纵向或成角畸形。96 例患者纳入研究,中位随访时间为 35 个月。共有 22 例(23%)患者发生并发症。机械性并发症包括:1 例(1%)无菌性松动,2 例(2%)不愈合,7 例(7%)结构并发症。非机械性并发症包括 1 例(1%)软组织并发症,4 例(4%)感染和 5 例(5%)肿瘤进展。2 例(2%)患儿出现儿科并发症。本研究表明,CF 板在骨肿瘤切除后的复杂重建中使用是安全的,其并发症发生率似乎较低。