Suppr超能文献

技术视频:使用 Scepter-Mini 球囊导管栓塞脊髓硬膜外动静脉瘘(Onyx-18)。

Technical video: Onyx-18 embolization of spinal epidural arteriovenous Fistula using the scepter-Mini balloon catheter.

机构信息

Goodman Campbell Brain and Spine, Ascension St Vincent Medical Center, Division of Interventional Neuroradiology, Indianapolis, IN, USA.

Goodman Campbell Brain and Spine, Ascension St Vincent Medical Center, Division of erebrovascular Neurosurgery, Indianapolis, IN, US.

出版信息

Interv Neuroradiol. 2024 Aug;30(4):604-605. doi: 10.1177/15910199221138633. Epub 2022 Nov 10.

Abstract

Spinal arteriovenous fistulas (AVFs) account for approximately 70% of all vascular spinal malformations and commonly develop in the lateral epidural space at the epidural /radicular venous junction. The fistula is located close to the spinal nerve root where a radiculomeningeal artery shunts to a radicular vein. Increased venous pressure leads to decreased spinal venous drainage and venous congestion causing progressive myelopathy, bowel/bladder incontinence and erectile dysfunction. Treatment consists of surgical occlusion of the intradural vein, or endovascular embolization, which has a reported success rate of 25%-75%. Endovascular failure can occur with inadequate embolic penetration of the nidus and the proximal segment of the draining vein, or premature reflux of the liquid embolic agent.The use of a dual-lumen balloon microcatheter offers advantage in these cases given the ability to push liquid embolysate more distally during balloon inflation. The Scepter Mini is a new dimethyl-sulfoxide (DMSO)-compatible dual-lumen balloon microcatheter with a distal-tip outer diameter of 1.6 Fr and a nominal balloon diameter of 2.2 mm, facilitating atraumatic navigation and safer balloon inflation. Limited neurointerventional experience using the Scepter Mini in predominantly cerebrovascular cases has reported favorable navigability and flow arrest Although Onyx is rarely used for spinal AVF embolization, success has been reported considering the well-known favorable experience in cerebral cases.We present one of the first cases of Onyx embolization of a spinal dural AVF through a Scepter Mini in a patient with progressively worsening lower extremity sensorimotor dysfunction. Operators should be aware of radiculomedullary arteries arising at the same level or at adjacent levels to avoid unintentional Onyx migration during balloon inflation.

摘要

脊髓动静脉瘘(AVF)约占所有血管性脊髓畸形的 70%,通常在硬膜外/神经根静脉交界处的外侧硬脊膜外间隙发育。瘘管位于靠近脊神经根的位置,其中一根脊神经根动脉分流到一根神经根静脉。静脉压升高导致脊髓静脉引流减少和静脉充血,导致进行性脊髓病、肠/膀胱失禁和勃起功能障碍。治疗包括手术闭塞硬脊膜内静脉或血管内栓塞,其报告成功率为 25%-75%。血管内治疗失败可能是由于微导管对病灶和引流静脉近端段的栓塞不完全穿透,或者液体栓塞剂过早反流。在这种情况下,使用双腔球囊微导管具有优势,因为在球囊膨胀过程中可以将液体栓塞剂推得更远。Scepter Mini 是一种新型二甲基亚砜(DMSO)兼容的双腔球囊微导管,其远端尖端外径为 1.6 Fr,标称球囊直径为 2.2 mm,便于进行无创伤性导航和更安全的球囊膨胀。在主要为脑血管病的病例中使用 Scepter Mini 的有限神经介入经验报告了良好的可操作性和血流阻断。虽然很少将 Onyx 用于脊髓 AVF 栓塞,但考虑到在脑病例中众所周知的良好经验,报告了成功。我们报告了首例通过 Scepter Mini 对脊髓硬脊膜 AVF 进行 Onyx 栓塞的病例之一,该患者的下肢感觉运动功能逐渐恶化。操作人员应注意与球囊膨胀同时出现的同一水平或相邻水平的脊神经根动脉,以避免在球囊膨胀过程中意外发生 Onyx 迁移。

相似文献

7
Onyx Embolization of Spinal Arteriovenous Fistula via Scepter Balloon.经 Scepter 球囊行 Onyx 栓塞治疗脊髓动静脉瘘。
World Neurosurg. 2020 Feb;134:62-66. doi: 10.1016/j.wneu.2019.10.112. Epub 2019 Nov 11.

本文引用的文献

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验