Changes in Light Disturbance Analyzer Evaluation in SMILE for High Myopia and Astigmatism.

出版信息

J Refract Surg. 2022 Nov;38(11):725-732. doi: 10.3928/1081597X-20221019-02. Epub 2022 Nov 1.

Abstract

PURPOSE

To study the objective change in light disturbance around a glare source using the Light Disturbance Analyzer (LDA) (Binarytarget Lda) and correlate this with the validated subjective quality of vision (QoV) questionnaire in small incision lenticule extraction (SMILE) for high compound myopic astigmatism.

METHODS

This was a prospective study recruiting 114 patients undergoing SMILE with attempted spherical equivalent refraction (SEQ) correction from -9.00 to -13.00 diopters (D), and cylinder up to 5.00 D. The LDA was used before and 3 and 12 months after surgery to evaluate the Light Disturbance Area, Light Disturbance Index, Best Fit Circle Radius, and Best Fit Circle Irregularity. Patients completed the Rasch-validated QoV questionnaire before and 12 months after surgery. Correlation analysis was performed between the LDA parameters and the QoV frequency, severity, and bothersomeness for halos and starbursts.

RESULTS

At 12 months, there was a non-statistically signifcant change of 11.9% for Light Disturbance Area and Light Disturbance Index and 6.5% for Best Fit Circle Radius. There was an increase of 81.9% for Best Fit Circle Irregularity ( = .017). Light Disturbance Area, Light Disturbance Index, and Best Fit Circle Radius correlated with bothersomeness for QoV halos, and with frequency, severity and bothersomeness for QoV star-bursts (P < .05), albeit with a low correlation coefficient ( < 0.13). There was no correlation between increase in Best Fit Circle Irregularity and the halo and starburst scores from the QoV questionnaire.

CONCLUSIONS

LDA Best Fit Circle Irregularity was found to increase following high myopic SMILE. Other LDA parameters appeared to increase, but a much larger sample would be required to find statistical significance. The change in LDA parameters was only weakly correlated with QoV halo and starburst metrics, representing the wide variation in inter-subject perception. .

摘要

目的

使用光干扰分析仪(LDA)(Binarytarget Lda)研究眩光源周围光干扰的客观变化,并将其与小切口透镜切除术(SMILE)治疗高度近视散光的验证主观视觉质量(QoV)问卷相关联。

方法

这是一项前瞻性研究,招募了 114 名接受 SMILE 手术的患者,试图矫正等效球镜(SEQ)从-9.00 至-13.00 屈光度(D),柱镜高达 5.00 D。在术前、术后 3 个月和 12 个月使用 LDA 评估光干扰面积、光干扰指数、最佳拟合圆半径和最佳拟合圆不规则度。患者在术前和术后 12 个月完成 Rasch 验证的 QoV 问卷。对 LDA 参数与 QoV 光晕和星爆的频率、严重程度和困扰程度之间进行相关性分析。

结果

术后 12 个月,光干扰面积和光干扰指数分别有非统计学意义的 11.9%和 6.5%的变化,最佳拟合圆半径增加 6.5%。最佳拟合圆不规则度增加 81.9%( =.017)。光干扰面积、光干扰指数和最佳拟合圆半径与 QoV 光晕的困扰程度相关,与 QoV 星爆的频率、严重程度和困扰程度相关(P <.05),但相关系数较低(<0.13)。最佳拟合圆不规则度的增加与 QoV 问卷中的光晕和星爆评分之间没有相关性。

结论

发现高度近视 SMILE 术后 LDA 最佳拟合圆不规则度增加。其他 LDA 参数似乎也有所增加,但需要更大的样本量才能发现统计学意义。LDA 参数的变化与 QoV 光晕和星爆指标相关性较弱,这代表了受试者之间感知的广泛差异。