Suppr超能文献

O 臂导航辅助脊柱畸形手术中椎弓根螺钉置钉的漂移现象的危险因素。

Risk Factors for the Drift Phenomenon in O-arm Navigation-Assisted Pedicle Screw Placement during Spinal Deformity Surgery.

机构信息

Department of Orthopaedic Surgery, Shanghai Changzheng Hospital, Second Military Medical University, Shanghai, China.

Department of Orthopaedic Surgery, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University, Shanghai, China.

出版信息

Orthop Surg. 2023 Jan;15(1):118-123. doi: 10.1111/os.13557. Epub 2022 Nov 16.

Abstract

OBJECTIVE

Intraoperative O-arm navigation systems improve the accuracy of spinal instrumentation placement. However, deviation of the pedicle screw from the guide line might occur. The aim of the present study was to explore the causes of and countermeasures for the drift phenomenon during pedicle screw implantation with the aid of an O-arm three-dimensional navigation system in spinal deformity surgery.

METHODS

This was a retrospective analysis of 341 patients with spinal deformity who underwent O-arm navigation system-assisted pedicle screw placement from July 2015 to June 2019. The patient's general condition, Cobb angle, apical vertebra position, softness index, spinal release status, fixed reference frame position, and distance between the navigation vertebral body and the reference frame were collected and compared by independent-samples t test or Pearson's chi-square analysis. The potential risk factors for the drift phenomenon were identified using binary logistic regression analysis.

RESULTS

The drift phenomenon occurred in 57 patients during the first navigation-assisted pedicle screw placement, for an incidence of 16.7% (57/341). There were significant differences in factors such as the apical vertebra position, softness index, spinal release status, and distance between the vertebral body and the reference frame when the drift phenomenon occurred (P < 0.05). Binary logistic regression analysis showed that the softness index, spinal release status, and distance between the vertebral body and the reference frame when drifting occurred were independent risk factors for the drift phenomenon during O-arm navigation-assisted pedicle screw placement.

CONCLUSION

During the use of an O-arm navigation system to assist with pedicle screw placement, pedicle screws should not be placed away from the reference frame, and spinal osteotomy and release should be performed after pedicle screw placement. In addition, the accuracy of O-arm navigation-assisted pedicle screw placement will be affected more in those with larger softness indices.

摘要

目的

术中 O 臂导航系统可提高脊柱内固定物放置的准确性。然而,椎弓根螺钉可能会偏离导丝。本研究旨在探讨 O 臂三维导航系统辅助脊柱畸形手术中椎弓根螺钉植入时漂移现象的原因及对策。

方法

回顾性分析 2015 年 7 月至 2019 年 6 月接受 O 臂导航系统辅助椎弓根螺钉置入的 341 例脊柱畸形患者的临床资料。收集患者一般情况、Cobb 角、顶椎位置、柔软度指数、脊柱松解状态、固定参考框架位置、导航椎体与参考框架之间的距离,采用独立样本 t 检验或 Pearson 卡方检验进行比较。采用二项逻辑回归分析确定漂移现象的潜在危险因素。

结果

在首次导航辅助椎弓根螺钉置入过程中,57 例患者出现漂移现象,发生率为 16.7%(57/341)。发生漂移现象时,顶椎位置、柔软度指数、脊柱松解状态、导航椎体与参考框架之间的距离等因素差异均有统计学意义(P<0.05)。二项逻辑回归分析显示,柔软度指数、脊柱松解状态和发生漂移时导航椎体与参考框架之间的距离是 O 臂导航辅助椎弓根螺钉置入时发生漂移的独立危险因素。

结论

O 臂导航系统辅助椎弓根螺钉置入时,螺钉不应远离参考框架,且应在椎弓根螺钉置入后进行脊柱截骨松解。此外,O 臂导航辅助椎弓根螺钉置入的准确性在柔软度指数较大的患者中受影响更大。