荷兰一家三级医疗中心开展眼眶斑块旋切术的初步经验。

Initial experience with orbital atherectomy in a tertiary centre in the Netherlands.

作者信息

den Dekker Wijnand K, Siskos Anastasios-Alexandros, Wilschut Jeroen M, Nuis Rutger-Jan, Scarparo Paola, Neleman Tara, Masdjedi Kaneshka, Ligthart Jurgen M R, Diletti Roberto, Daemen Joost, Van Mieghem Nicolas M

机构信息

Department of Cardiology, Thoraxcenter, Erasmus University Medical Center, Rotterdam, The Netherlands.

出版信息

Neth Heart J. 2023 May;31(5):196-201. doi: 10.1007/s12471-022-01742-3. Epub 2022 Dec 12.

Abstract

BACKGROUND

In January 2021, the Diamondback 360 orbital atherectomy (OA) system received CE mark approval and became available in Europe. The first procedure in Europe was performed at the Thoraxcenter, Erasmus Medical Center, Rotterdam, the Netherlands.

AIMS

To report the procedural safety and efficacy of the initial experience with OA in a tertiary care institution in the Netherlands.

METHODS

Patients with de novo severely calcified coronary artery disease who were treated with intended invasive imaging-guided OA were included in a prospective single-centre registry. Device success, defined as less than 50% stenosis after OA, and procedural success, defined as successful stent implantation with less than 50% residual stenosis, were evaluated. Calcium debulking effects were assessed by invasive imaging. Safety was assessed up to 30 days after the index procedure.

RESULTS

Between February 2021 and June 2021, 29 patients with a total of 39 coronary arteries underwent OA. Target lesions were heavily calcified with a mean length of 32 mm and a calcium arc of 320 degrees. Invasive imaging was applied in all but one patient and 36 vessels. Superficial sanding was observed in almost all vessels (90%) and fracturing of deeper medial calcium in more than half of the vessels (63%), with a device success of 66% and procedural success of 94%. The mean stent symmetry index was 0.84, indicating good circular stent expansion. No primary safety events occurred during 30 days of follow-up.

CONCLUSION

Our initial experience with OA for heavily calcified coronary lesions demonstrated favourable debulking effects and plaque modification, with high procedural success and clinical safety.

摘要

背景

2021年1月,“响尾蛇360”轨道旋磨术(OA)系统获得CE标志认证并在欧洲上市。欧洲的首例手术在荷兰鹿特丹伊拉斯姆斯医学中心胸科中心进行。

目的

报告荷兰一家三级医疗机构首次使用OA的手术安全性和有效性。

方法

将接受有创影像引导下OA治疗的初发严重钙化冠状动脉疾病患者纳入前瞻性单中心登记研究。评估器械成功率(定义为OA术后狭窄率小于50%)和手术成功率(定义为成功植入支架且残余狭窄率小于50%)。通过有创影像评估钙化减容效果。在索引手术30天内评估安全性。

结果

2021年2月至2021年6月,29例患者共39支冠状动脉接受了OA治疗。靶病变严重钙化,平均长度为32毫米,钙化弧为320度。除1例患者和1支血管外,其余均应用了有创影像。几乎所有血管(90%)均观察到表面打磨,超过半数血管(63%)出现深层中层钙化破裂,器械成功率为66%,手术成功率为94%。平均支架对称指数为0.84,表明支架呈良好的环形扩张。随访30天内未发生主要安全事件。

结论

我们对严重钙化冠状动脉病变进行OA的初步经验显示出良好的减容效果和斑块修饰效果,手术成功率高且临床安全性良好。