Abstract

OBJECTIVE

The purpose of this study was to investigate the significance of mismatch negativity (MMN) by comparing high-resolution electroencephalogram signals from tinnitus patients and healthy controls.

METHODS

The study included eight subjects with chronic subjective idiopathic tinnitus and seven healthy controls. Participants with clinical speech (512-2,000 Hz) hearing thresholds less than 25 dB HL and with negative Hospital Anxiety and Depression Scale scores were included in the study. The E-Prime 2.0 software and a 256-electrode EGI Net Station system were used to evoke and record the MMN signal, and the amplitude and latency parameters of the MMN responses were compared between the two groups.

RESULTS

From 150 ms, there was a significant difference between the amplitude of standard stimulation and deviation stimulation, and the event-related potential amplitude under deviation stimulation in the tinnitus patient group was significantly different from that in the healthy group. The MMN amplitude of the FCz electrode was statistically significantly lower in the tinnitus patients compared to healthy controls.

CONCLUSION

MMN has application value in the evaluation of abnormal electrical activity in the auditory pathway, and electroencephalograms are feasible for follow-up monitoring after acoustic therapy.

摘要

目的

本研究旨在通过比较耳鸣患者与健康对照者的高分辨率脑电图信号,探讨失匹配负波(MMN)的意义。

方法

该研究纳入了8名慢性主观性特发性耳鸣患者和7名健康对照者。研究纳入了临床言语(512 - 2000赫兹)听力阈值低于25分贝听力级且医院焦虑抑郁量表得分呈阴性的参与者。使用E - Prime 2.0软件和256电极EGI Net Station系统来诱发和记录MMN信号,并比较两组之间MMN反应的幅度和潜伏期参数。

结果

从150毫秒起,标准刺激与偏差刺激的幅度存在显著差异,耳鸣患者组中偏差刺激下的事件相关电位幅度与健康组有显著差异。与健康对照者相比,耳鸣患者中FCz电极的MMN幅度在统计学上显著更低。

结论

MMN在评估听觉通路异常电活动方面具有应用价值,脑电图对于声治疗后的随访监测是可行的。