Lopez Santiago, Pillai Lakshmikumar, Inkollu Sashi
Heart and Vascular Institute, West Virginia University School of Medicine, Morgantown, WV.
J Vasc Surg Cases Innov Tech. 2022 Nov 15;8(4):861-864. doi: 10.1016/j.jvscit.2022.11.002. eCollection 2022 Dec.
The use of Heli-FX EndoAnchors (Medtronic CardioVascular, Santa Rosa, CA) with the Endurant II stent graft (Medtronic CardioVascular) has been approved by the Food and Drug Administration for juxtarenal abdominal aortic aneurysms with neck lengths ≤4 mm. The use of this technique of endosuture aneurysm repair has not been previously described in the setting of rupture. We have presented two cases of successful endosuture aneurysm repair of ruptured juxtarenal AAAs.
美敦力心血管公司(位于加利福尼亚州圣罗莎)生产的Heli-FX腔内锚定器与Endurant II覆膜支架移植物联合使用,已获美国食品药品监督管理局批准,用于治疗颈部长度≤4毫米的近肾型腹主动脉瘤。此前尚未有关于在破裂情况下使用这种腔内缝合动脉瘤修复技术的描述。我们报告了两例成功运用腔内缝合技术修复破裂近肾型腹主动脉瘤的病例。